Troubleshooting: Mechanical and Electrical Problems
Trouble
Uneven depth of cut side to side.
Board thickness does not match depth of cut scale.
Chain is jumping.
Machine will not start/restart or repeatedly trips circuit breaker or blows fuses.
Probable Cause | Remedy | |
|
| |
Knife projection from cutterhead is | Adjust knife projection. | |
incorrect (15S only). | ||
| ||
|
| |
Table not parallel to cutterhead. | Adjust table/cutterhead parallelism. | |
|
| |
Depth of cut scale is incorrect. | Adjust depth of cut scale. | |
|
| |
Inadequate tension. | Adjust chain tension. | |
|
| |
Sprockets misaligned. | Align sprockets. | |
|
| |
Sprockets are worn. | Replace sprockets. | |
|
| |
No incoming power. | Verify power connections to planer. | |
|
| |
| When planer overloads on the circuit | |
| breaker built into the motor starter, it | |
| takes time for the machine to cool | |
Overload automatic reset has not | down before restart. Allow unit to | |
reset. | adequately cool before attempting | |
| restart. If problem persists, check | |
| amp setting on the motor starter | |
| inside the electrical box. | |
|
| |
| One cause of overloading trips which | |
| is not electrical in nature is too heavy | |
| a cut. The solution is to take a lighter | |
| cut. | |
| If too deep a cut is not the problem, | |
Planer frequently trips. | then check the amp setting on the | |
overload relay. Match the full load | ||
| ||
| amps on the motor as noted on the | |
| motor plate. | |
| If amp setting is correct then there is | |
| probably a loose electrical lead. | |
| Check amp setting on motor starter. | |
| Verify that planer is on a circuit of | |
Building circuit breaker trips or fuse | correct size. If circuit size is correct, | |
there is probably a loose electrical | ||
blows. | ||
lead. Check amp settting on motor | ||
| ||
| starter. | |
|
| |
| Go through all the electrical | |
| connections on the planer including | |
| motor connections, verifying the | |
Loose electrical connections. | tightness of each. Look for any signs | |
| of electrical arcing which is a sure | |
| indicator of loose connections or | |
| circuit overload. | |
|
|
24