Fostex FM-3 Meter status display, Parameter setting procedure, + or key, Peak meter on/off

Page 19

Meter status display

On the meter status display, not only you can see the cur- rent status of the metering, but also you can set param- eters. The following shows the default setting when the unit is shipped.

(1) Peak meter ON/OFF

You can enable or disable the peak meter function for the left and right channels independently.

(2) VU meter reference (0 VU) level

You can set the reference level for the left and right channels indepen- dently.

(3) Threshold level of the peak over indicator

You can set the peak threshold level for the left and right channels independently.

(4) Internal battery type

You can set the battery type between alkaline or nickel hydride.

Parameter setting procedure

(1)While the meter status display is shown, press the [EDIT] key long enough.

The peak meter on/off setting of the left channel (“”) starts flashing. You can now edit the peak meter on/off setting of the left channel.

Flashing

<Memo>: By bringing up the meter status display while the unit is receiving a signal, you can edit pa- rameters while checking movement of the VU and peak meters.

(2)While any parameter is flashing, press the [EDIT] key to select the flashing parameter.

Pressing the [EDIT] key selects the flashing parameter in the following order.

Lch “PK”

Lch “0VU”

Lch “OVR”

BAT TYPE

 

Rch “PK”

 

Rch “OVR”

Rch “0VU”

(3)While the desired parameter to be edited is flashing, you can select a desired value using the

[+] or [-] key.

In the following display example, both the left and right peak meters are set to “”.

See “Parameter details” below for the available options of each parameter.

Flashing

(4)After editing parameters, press the [EDIT] key long enough to stop flashing.

(5)Press the [EDIT] key to exit the status display mode.

Parameter details

Peak meter on/off

The meter display shows both VU and peak metering (de- fault).

The meter display shows only VU metering. The peak me- tering is not shown.

VU meter reference level

The default value is “0 dB”. You can select between “0 dB” and “+7 dB” in 1 dB steps.

<Example>: If you set the reference level to “+5”, the level at 0 VU is +5 dB higher than the refer- ence level.

<Memo>: It is recommended to change the reference level appropriately when an external audio device connected to the outputs of the unit has enough headroom. Normally, set it to “0”.

<Memo>: If you set the reference level other than “0”, “+” is lit beside the “0” position of the VU meter, showing that the 0 VU level is not the reference level.

+

Stereo VU meter

+

Left channel VU meter

19

Image 19
Contents Model FM-3 Table of contentsAppliance has been dropped, or the enclosure damaged Safety InstructionsImportant Safety Instructions Do not install the unit in the following conditions PrecautionsMixer section features Main featuresBasic operations Preparation of power supplyBattery box compartment Battery box compartment SymbolPreparation of input channels Preparation of output channelsPreparation of metering Set the pan and HPF switches of each channel if required Input setting Master fader reference settingPreparation of monitoring Block diagram Front panel section Names and functionsFactory preset values Monitor select switchHeadphones level control Limiter switch ON, OFF, LinkLeft side panel section Right side panel section Key darker Adjusting the display brightnessDisplay You can select from OFF and 1 throughSelecting the status display Selecting the meter modePress the + or key to select the desired meter mode Press the Edit key to exit the status display modeTo ST Buss switch status Microphone power supply switch statusInput select switch status HPF switch statusSUB OUT level switch Main OUT L, R level switches Limiter switch statusAUX OUT switch status AUX OUT level switchLong enough to stop flashing Limiter parameter settingValues Peak meter on/off Parameter setting procedureMeter status display + or keyInitializing the flash memory System status displayOthers SpecificationsInputs/Outputs PerformanceGeneral External dimensions Affect of Immunity on This Equipment Declaration of EC DirectiveFor the US Customers only Fostex America Limited Warranty Fostexco