M-Audio Axiom Pro manual All, Off

Page 50

Axiom Pro User Guide

 

 

45

Parameter:

MIDI Port

Value Range:

O, A, A&O, B, B&O, A&B, All, Off

 

Each of the four zones can be individually configured to transmit MIDI data on any combination of

 

Axiom Pro ports:

 

• A

Axiom Pro 6111 USB A

 

• B

Axiom Pro 6111 USB B

 

• O

Axiom Pro 6111 MIDI Out (External MIDI port)

 

All

MIDI data is transmitted on all ports

 

Off

MIDI data is not transmitted

Parameter:

Program

Value Range:

0-127

 

This parameter sends Program Change MIDI messages on your selected keyboard zone’s MIDI

 

output channel when an Axiom Pro patch is loaded. Note that Program Change messages are only

 

sent on active zones. Please see the “Edit Mode > Zones” section of this guide to learn how to

 

activate/deactivate zones.

Parameter:

BankLSB

Value Range:

0-127

 

This parameter sends Bank LSB messages on

 

your selected zone’s MIDI output channel when

 

an Axiom Pro patch is loaded. Note that Bank

 

LSB messages are only sent on active zones and

 

will not have any effect until a Program Change

 

message is sent.

NOTE: If you load an Axiom Pro patch containing program change, bank LSB, or bank MSB messages for the zones, each zone will transmit its assigned program change or bank LSB/MSB message when the patch is loaded. If you would like to load a patch without sending these messages, make sure that the keyboard icon is unchecked on the Load page. Please see the “Loading Patches” section in the “Saving and Loading your Axiom Pro Patches” chapter to learn more about this topic.

Parameter:

BankMSB

Value Range:

0-127

 

This parameter sends Bank MSB messages on your selected zone’s MIDI output channel when an

 

Axiom Pro patch is loaded. Note that Bank MSB messages are only sent on active zones and will

 

not have any effect until a Program Change message is sent.

11The 25 and 49-note versions of Axiom Pro will appear as “Axiom Pro 25” and “Axiom Pro 49” respectively.

Image 50
Contents Axiom Pro Connection Diagram Controls and ConnectorsTroubleshooting Appendices Technical Info WarrantyHow To Quick Reference Axiom Pro User Guide Introduction Differences between Axiom Pro 25/49/61What’s in the Box Product Features and Specifications Minimum System Requirements Mac OS X users Driver InstallationWindows XP/Vista Users Windows XP, Vista and Mac OS X 10.4 Tiger users Axiom Pro Class-Compliant Port Names per Operating SystemWhen using Axiom Pro with a computer Connection DiagramHosted Mode Standalone Mode When using Axiom Pro without a computerControls and Connectors Top Panel OverviewAxiom Pro Rear Panel Overview LCD Screen Using Axiom ProOverview and Basic Operation Function Buttons and Soft Keys Axiom Pro 49/61Hold F1-4Load+Save Edit+Zone/GrpKey Message KeysSaving and Loading Axiom Pro Patches Saving PatchesLoading Patches Using Axiom Pro with a Computer Software ConfigurationHyperControl Installation and Usage HyperControl ModeAbout HyperControl Mode Edit Mode Edit Mode Main Menu This top-level menu appears when Axiom Pro enters Edit modeValue Range Edit Mode GlobalParameter Parameter OctaveVelocity Settings Description Keys LowAdvanced Midi users Parameter DataWhy are BankLSB/BankMSB messages needed? Editing Name Parameters Edit Mode ControlParameter Name Value Range Varies Sub-parameters such as Note OnOff Toggle or Rel. Bin Offset Control Assignment List Control Assignment List Control Assignment List Type Control Type Midi Ch. Param. a Param B Description About the Channel sub-parameter About the Entry sub-parameter About the Endless Encoders Tip GlobalParameter Curve Velocity Settings Description Pads NormalParameter Value Range VariesEdit Mode Group Encoder Zone Edit Mode Group Slider An Unsynchronized Slider Synchronized SliderEdit Mode Group Numerical Keypad To activate or deactivate a zone Edit Mode ZonesTo select the range of a keyboard zone Edit Mode Zones Data GlobalAll OffEdit Mode Midi Parameter SysExUSB About Sysex and Snapshot data Troubleshooting Axiom Pro User Guide Patch # Name Encoders Sliders Appendix a Axiom Pro Factory Patch settingsAppendices About the F-KeysAxiom Pro Control DAW PatchesPatch 1 GM Patch Axiom Pro Numerical Keypad Midi Message Save session Encoders and Sliders Patch 20 Numbers Axiom Pro Numerical Keypad Ascii Character Appendix B Keyboard Velocity Curves Axiom Pro Keyboard Velocity Curve High Axiom Pro Keyboard Velocity Curve High Range Appendix C Drum Pad Velocity Curves Axiom Pro Drum Pads Velocity Curve 3 Steps Axiom Pro Drum Pads Velocity Curve Fixed Appendix D Midi Implementation Appendix E Useful Midi Data Tables E1 General Midi Instruments Program Numbers 14E2 General Midi Note Numbers E3 Roland GS And Yamaha XG Nrpn MessagesE6 General Midi Drums Note assignments E4 GM2 Reverb TypesE5 GM2 Chorus Types Appendix F General Midi Continuous Controller CC Numbers Appendix G Hexadecimal Conversion Chart Technical Info Warranty Warranty Terms Warranty RegistrationAudio USA