Options are then set by pressing a letter key followed by a number key followed by the RETURN key. For example to select an RS232 baud rate of 1200 use the following:
Whilst within configuration mode press | B1f |
The num, caps and scroll lock lights will indicate correct acceptance of the command as follows:
∙In compensation / configuration the num, caps and scroll lock lights will flash in sequence.
∙After pressing the first key of a command sequence the num, caps and scroll lock lights will all be illuminated.
∙After pressing the second key of a command sequence the num and caps lock lights will be on and the scroll lock light will be off.
∙After pressing RETURN the command will have been accepted and the num, caps and scroll lock lights will go back to flashing in sequence.
When you have finished selecting options, return to normal operation by pressing
f
2.10 Summary of AdderLink configuration options
Full details of each of the configuration options and their uses are given in section 4.
B1f
B2f
F1f
F8f
-Set RS232 baud rate to 1200 (default) (see section 4.1)
-Set RS232 baud rate to 9600
-Query AdderLink firmware version (see section 3.11)
-Resets all