AMC manual Installing the XOi Digital Home System, Prewire

Page 9

INSTALLING THE XOi DIGITAL HOME SYSTEM

1. Prewire

The XOi uses Cat-5 cable for keypad control and either two- or four-conductor 16- gauge speaker wire. All the wire is homerun from each zone to the XOi.

2.The XOi digital home systems require Cat-5, unshielded, twisted pair (UTP), for communication between the keypads/display pads and the main XOi unit. Each end of the wire is terminated with an RJ45 connector.

The XOi system can accommodate 500 total feet of Cat-5 cable for each zone. For the most reliable operation, it is best that no single run of Cat-5 exceeds 250 feet. The correct wiring scheme for the Cat-5 cable is standard EIA/TIA 568A. Properly terminating the Cat-5 cable is crucial for the operation of the system. It is very important to use a good quality crimp tool, and testing each end to end run with Cat- 5 wire tester will insure that your system operate flawlessly, Fig. 1.

Fig.1: EIA 568A wiring scheme for Cat-5 Cable

Pin #

1.Green Stripe

2.Green

3.Orange Stripe

4.Blue

5.Blue Stripe

6.Orange

7.Brown Stripe

8.Brown

Note: Colors listed as "stripe" are a white wire with a colored stripe.

8

Image 9
Contents Page Page Features of the Amctm model XOi * System for total 4 Zones Application and Feature List12VDC Rear Panel CONNECTIONS/FRONT Panel ControlsFront Panel Controls Rear Panel ConnectionsSource Selection PowerJK2 RJ45 to XOi Rear Panel JK3 RJ45 To Another XK110. JK4 RJ45 To SUB Zone Power On & Off Remote ControlVolume Mute & Mute On & Mute OffPrewire Installing the XOi Digital Home SystemSpeaker Wire Termination at XOi IR Outputs Installing the XOiVolume Reset Keypad XK1 and Zone SetupEQ Control and Source Grouping All offRJ-11 Connection Physical SpecificationsSafety Instruction Weltronics Corp