Peavey PZS 140 Channel 3 Thru 5 Zone Assignment Switches, Master Zone Level Controls, Power LED

Page 5

7.CHANNEL 1 ZONE ASSIGNMENT SWITCHES Switches used to route the signal to the desired zone.

OPERATION NOTE: Anytime channel one is assigned to a zone and a signal is present in channel one all other channels assigned to that zone will be ducked by 20 dB. This enables channel one to be used for emergency override signals. This function can be disabled by turning the threshold control completely counter-clockwise.

8.CHANNEL 2 ZONE ASSIGNMENT SWITCHES Switches used to route the signal to the desired zone.

OPERATION NOTE: Anytime channel two is assigned to a zone and a signal is present in channel two, all other channels assigned to that zone will be ducked by 20 dB (except channel one). This function can be disabled by turning the threshold control completely counter-clockwise.

9.CHANNEL 3 THRU 5 ZONE ASSIGNMENT SWITCHES

Switches used to route the background audio signal to the desired zone. Selecting a particular zone button routes the audio source associated with that particular channel to the desired zone. The zone assignment switches can be used to route the audio to one or more zones if desired.

10.MASTER ZONE LEVEL CONTROLS

Controls the signal level being sent to each zone amplifier. Normally these controls should be set at the 12:00 position and the overall system levels set using the various channel level controls. This setting yields the best compromise for system noise performance and signal headroom.

11.ZONE ACTIVE LEDS

Indicates whenever any signal activity is occurring in that particular zone. These LEDs will light whenever a signal level above 50 mW RMS occurs in the associated zone power amp. These indicators are helpful for setting up the zone signal levels.

12.ZONE CLIP LEDS

Indicates clipping may be occurring in that particular zone. These LEDs will light whenever a signal level of 35 W RMS occurs in the associated zone. If these LEDs occasionally, flash only on peaks of the music or paging signal, audible clipping is probably not occurring. If these LEDs come on and stay on, then the power amps are clipping and audible distortion is probably occurring in that zone.

OPERATION NOTE: These LEDs are only an indication of the level being sent to the power amps from the preamp. If a signal processor is used in the insert point, it must be set up in a way that it does not add/reduce the system gain. If the signal processor changes the signal level between the preamp and power amp the LEDs are no longer accurate.

13.POWER SWITCH

Rocker type switch, depress to ÒonÓ position to power unit.

14.POWER LED

Indicates when AC power is being supplied to the unit and the power switch is ÒonÓ.

5

Image 5
Contents PZ S 1 4 Page Description FeaturesSignal Presence LED Front Panel Front Panel Features Channel Level ControlsChannel LOW EQ Control Bass Channel High EQ Control TreblePower Switch Channel 3 Thru 5 Zone Assignment SwitchesPower LED Master Zone Level ControlsFuse Back Panel Back Panel FeaturesAC Line Cord Socket Channel 1 and 2 XLR InputsChannel 3 Thru 5 RCA Inputs Channel 1 and 2 HI-Z InputChannel 3 Thru 5 HI-Z Inputs Channel 3 Thru 5 LOW-Z InputsPower AMP Outputs Link SwitchZone Loop OUT/IN See DrawingsPower Supply Power OutputWeight OutputsPZSª 140 Level Diagram PZSª-140 External Power Amp Effect Patches Output Typical Small Music/Paging System Limited Warranty Page Important Safety Instructions Architectural ACOUSTICS¨