23.ZONE LOOP OUT/IN

A send/return patch point for external effects or EQ. The loop out terminals are line level preamp outputs following the master level stages of each zone. The Loop In terminals are line level power amplifier input points for each zone power amp. Both the Loop Out and Loop In are unbalanced signals requiring only a single conductor shielded cable for patching to the external device. Wire the cables as follows:

Cable shield- ground Cable conductor-out (or in)

SEE DRAWINGS page 11.

Note: Both cables share the same ground terminal. The Loop Out has a low source imped- ance to drive any reasonable device, and the in Loop In is a relatively high impedance input to not load down any reasonable device. It is recommended that all such external effects or EQ devices be in the same rack as the PZS.

24.LINK SWITCH

When the link switch is in the ÒinÓ position, the mixer preamp signal is routed directly to the zone power amps. When the link switch is in the ÒoutÓ position the signal is routed to the Loop Out. This signal can then be sent to an external processor or power amp. If it is sent to an external processor, it can be returned to the Loop In connection to be amplified by the internal zone amplifier.

25.600 OHM BALANCED OUTPUTS

A balanced output to drive additional power amplifiers. The PZS 140 has four 35 W RMS power amplifiers built in. For small installations, this is an adequate power distribution system, but for larger systems, external power amplifiers may be added to supply the extra power required. In this case, the external power amplifiers can be driven from this 600 ohm balanced line level output without causing unwanted ground loops or hum problems. A two- conductor shielded cable should be wired as follows:

Cable shield- ground Conductor 1- 600-ohm positive Conductor 2- 600 ohm negative

In this case, conductor one should be wired to be the positive input feed for the external power amp, and such amp connections can be wired either balanced or unbalanced.

SEE DRAWINGS page 12.

26.POWER AMP OUTPUTS

Outputs for speaker connections. Each power amplifier has a 4-ohm direct output, and a tran- former isolated 8-ohm, 25- and 70-volt outputs.

8

Image 8
Contents PZ S 1 4 Page Features DescriptionFront Panel Front Panel Features Channel Level Controls Signal Presence LEDChannel LOW EQ Control Bass Channel High EQ Control TrebleChannel 3 Thru 5 Zone Assignment Switches Power SwitchPower LED Master Zone Level ControlsBack Panel Back Panel Features FuseAC Line Cord Socket Channel 1 and 2 XLR InputsChannel 1 and 2 HI-Z Input Channel 3 Thru 5 RCA InputsChannel 3 Thru 5 HI-Z Inputs Channel 3 Thru 5 LOW-Z InputsLink Switch Power AMP OutputsZone Loop OUT/IN See DrawingsPower Output Power SupplyWeight OutputsPZSª 140 Level Diagram PZSª-140 External Power Amp Effect Patches Output Typical Small Music/Paging System Limited Warranty Page Important Safety Instructions Architectural ACOUSTICS¨