ETA Systems ETA-ECS6RM ECM-RACEWY6 ECM Housing, ECM-3BP Module Cover Plate, ECM-ACIN Wire Kit

Page 14

ETA-ECS6RM

Electrical Control Sequencer

ECM-RACEWY6 ECM Housing

The ETA-ECM20 and ETA-ECM20M require an electrical housing. The ECM-RACEWY6 holds up to 6 ECM modules. There are standard ¾" and 1" electrical knockouts on the bottom of the raceway to support standard electrical mounting hardware. Since the Raceway can house 6 ECM modules there can be 6 separate 20A AC legs coming into the Raceway for a total of 120A of power distribution or it could be as simple as one 20A leg. Note: All electrical wiring must be done by a certified electrician.

All cover plates must be secured tightly. There shall be no open slots. Blank cover plates are available. Top and bottom mounting tabs are incorporated to mount inside an Atlas Rack. All rack mount rails are designed to be breakaway, if they are not needed. Simply bend the tab back and forth until the tab breaks away. Be careful of sharp edges.

ECM-3BP Module Cover Plate

The ECM- RACEWY6 can hold up to 6 ETA-ECM20 / ETA-ECM20M Modules, however it is ok to use less than 6 modules. The open slot on the ECM-RACEWY6 can be covered up using an ECM Module Blank Plate cover. Two of these are included with the ECM-RACEWY6. If not needed, discard them. If additional Blank Plates are required they can be purchased in packages of three.

ECM-ACIN Wire Kit

ETA offers a wire kit of stranded 12-guage UL wire for wiring the ETA-ECM20 Modules together plus additional length for wiring the incoming AC to an AC Mains panel. 140" of each color of Green, White and Black are included. Note: As a reference, It takes around a foot of wire between ETA-ECM20 modules, if they are wired on the same incoming AC Main. It is highly recommended that the wire needed for the job is carefully measured. It may take more than one ECM-ACIN wire kit depending on how many AC Mains and the distance from the AC Mains Panel. It is not necessary to use Atlas ECM-ACIN wire kit as long as it is 12-gauge and UL listed.

ETA-ECM20M 20A AC Control Module

The features, data wiring and the functionality of the ETA-ECM20M are the same as the ETA-20SH and the ETA-15SH. The ETA-ECM20M is designed to be installed in the ECM-RACEWY6. Read above for operation details.

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800-321-6699 • Fax: 800-996-3821

– 14 –

ETAsys.com

Specifications are subject to change without notice.

Image 14
Contents ETA-ECS6RM Table of Contents Safety Instructions ETA-ECS6RM Introduction Applications ETA-ECS6RM KEY FeaturesECM Modules KEY Features Unit Activation Mode LEDs Front PanelETA-ECS6RM Rear Panel ETA-ECS6RM ECM Data Wire and Distance ECM Model FeaturesECM Indicator and Part Description AC Mains Power Cord 9 3m 120V 15AETA-ECS6RM Accessory Items AP-GNL18 LED Gooseneck LampECM-3BP Module Cover Plate ECM-RACEWY6 ECM HousingECM-ACIN Wire Kit ETA-ECM20M 20A AC Control ModuleETA-ECM20 20A AC Control Module No Current Monitoring ECS-KSW6ETA-ECS6RM Wiring Configuration OUTCH6 CH5 CH4 CH3 Examples ETA-ECM20/M20RW Module Wiring Configurations ExampleAction Needed TroubleshootingIssue 2 ECM module AC Fault LED is Illuminated on the ECM Possible Cause #2Possible Cause #3 ETA-ECS6RM Specifications ETA-ECS6RM ETA-ECS6RM Limited Warranty Service