ETA Systems specifications ETA-ECS6RM Specifications

Page 21

 

ETA-ECS6RM

Electrical Control Sequencer

ETA-ECS6RM SPECIFICATIONS

 

General

 

Type

Power Sequencer Controller

Sequencer Sections

6

Relay Sections

6

Sequence Timing

Unit Settings of 1, 3 or 6 Seconds

Unit Link

3

Power Supply

External Wide Rage 100V–240VAC, UL Approval

Power Consumption

.8W

RoHS Compliant

Yes

Dimensions

H 1.75" x W 19" x D 10"

Weight

7 lbs - 3.1kg

Front Panel

 

Lights

XLR Socket to Provide 12VDC for Optional 16" Atlas Power Gooseneck

 

Lamp, AP-GNL18. (Qty 1 Included)

LED Light Switch

Two Position On/Off

Activation Switch

Momentary

AC Mains Voltmeter

Three Digits Digital

AC Mains Current Meter

Three Digits Digital

Indicators

System On, External Trigger Mode, Slave Mode

Channel Selection

Momentary Switches

Channel Selected Indicator

Single LED Per Channel, Total Six LEDs

Activation Indicators

Six Bi-Color LEDs, One For Each Channel

Rear Panel

 

Sequenced Activation / Status Signal Port

Six Channels Interconnect port. Trigger Out and Status Signal Return, Euro /

 

Phoenix Type Connector

Remote Activation Trigger

5-24VDC Continuous 10 mA, Switch Contacts, Euro /

 

Phoenix type Connector

Sequenced Relay Contacts

Six Channels, Single Relay Contact SPST Each Channel. Euro /

 

Phoenix Type Connector

Sequence Time Selection

Setting 1,3,6 Seconds, Dip Switch Select

System Master/Slave Assignment

Master

 

Slave Unit 1

 

Slave Unit 2

 

Dip Switch Select

System Control Loop In/Out

One IN Control Port, One Loop OUT Control Port, for Slave or Master, Three

 

Units Can Be Linked. Connector RJ45 (Not an Ethernet Connection)

EVS Bypass

Extreme Voltage Shut Off Enable / Disable, Dip Switch Assign

LED Light Socket

XLR Socket to Provide 12VDC for Optional 16" Gooseneck Lamp, AP-GNL18

LED Light Switch

Two Position On/Off

DC Input Jack

External Power Supply, Wide Range 100V–240VAC, 20V DCV, UL Listed

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800-321-6699 • Fax: 800-996-3821

– 21 –

ETAsys.com

Specifications are subject to change without notice.

Image 21
Contents ETA-ECS6RM Table of Contents Safety Instructions ETA-ECS6RM Introduction ETA-ECS6RM KEY Features ECM Modules KEY FeaturesApplications Front Panel Unit Activation Mode LEDsETA-ECS6RM Rear Panel ETA-ECS6RM ECM Model Features ECM Data Wire and DistanceAC Mains Power Cord 9 3m 120V 15A ECM Indicator and Part DescriptionAP-GNL18 LED Gooseneck Lamp ETA-ECS6RM Accessory ItemsECM-ACIN Wire Kit ECM-RACEWY6 ECM HousingECM-3BP Module Cover Plate ETA-ECM20M 20A AC Control ModuleECS-KSW6 ETA-ECM20 20A AC Control Module No Current MonitoringOUT ETA-ECS6RM Wiring ConfigurationCH6 CH5 CH4 CH3 Example Examples ETA-ECM20/M20RW Module Wiring ConfigurationsIssue 2 ECM module AC Fault LED is Illuminated on the ECM TroubleshootingAction Needed Possible Cause #2Possible Cause #3 ETA-ECS6RM Specifications ETA-ECS6RM ETA-ECS6RM Service Limited Warranty