Atlas Sound 1, ECM-20M, ECM-RACEWY6, ECM-30 specifications ECM Data Wire and Distance

Page 15

Owner’s Manual

ECM-RACEWY

ECM-20, ECM-20M, & ECM-30

 

 

 

ECM Data Wire and Distance

There are six ECM control ports on the ECS-6RM and up to six ECM Modules can be connected to the ECS-6RM. The different types of ECM Modules require the same interface connectivity to the ECS-6RM. All ECM Modules and be interchange with the ECS-6RM. For connection between the ECS-6RM and an ECM module use a 5 conductor cable that is a minimum of 22 gauge wire. We suggest using CAT5 cable due to the common availability and low cost. Pay special attention to the port connections and DO NOT MISS WIRE or damage may occur. The distance between the ECS-6RM and the ECM Module can be up to 1000ft.

ECM Module Activation Without Using an ECS-6RM or an ECS-3 Controller

Any of the ECM-20, ECM-20M, ECM-30, ECM-15SH or the ECM-20SH Modules can be triggered to activate without using an ECS type Controller. Any DCV supply will activate the ECM by applying DCV 5-24VDC to the “+” and “GND” terminals. An external switch will also activate an ECM by applying a contact to short terminals “+” and “D” together. Note: The EVS and Voltage monitoring will be disabled using either of these methods.

The ECM can be used as standalone unit for local equipment protection. It does not need to be connected to an ECS-6RM to operate. You still get protection against AC spikes from short power surges and you get all the EMI/RFI power conditioning filtering. Without connecting to an ECS-6RM, the ECM does not utilize the Extreme Voltage Shutdown (EVS) protection and the Voltage and Current Status readings To active the ECM via an external contact closure or switch plate, set the slide switch to “External Trigger” and apply the contacts across terminals “+” and “D” shorting them together.

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 15 –

AtlasSound.com

Specifications are subject to change without notice.

Image 15
Contents ECM-RACEWY6/3/1 Table of Contents Important Safety Instructions ECM-RACEWY Introduction ECM-RACEWY Key Features ECM Module Key FeaturesApplications Raceway AC Inlet Knockouts Raceway ECM HousingRaceway Dimensions Raceway AC Ground StudRaceway Mounting Rails Incoming AC LED External Trigger/Manual On SwitchAC Fault LED Trigger/Status Port Pin IdentificationTrigger/Status Port Pin Identification ECM-30 Front Panel FeaturesInternal Features of the ECM Modules ECM Electrical Control ModulesDifferences Between the ECM-20 & ECM-20M Modules ECM-ACIN Wire Kit Wiring the ECM Control ModulesECM-3BP Module Blank Cover Plate ECM-20/ECM-20M Module System Wiring Configuration Example 1 Single 20A AC LineExample 2 Dual 20A AC Line 40A ECS-6RM Wiring Configuration Activating an ECM via ECS-6RM Relay ContactsExample ECM Data Wire and Distance ECM Troubleshooting Possible CauseAction Needed Mechanical ECM-RACEWY SpecificationsECM-20/ECM-20M Specifications Technical DataFront Panel ECM-30 Specifications Service Limited Warranty