Owner’s Manual |
| |
| ||
|
| |
Type | Power Conditioner Suppressor Module | |
RoHS Compliant | Yes | |
Safety Listings | UL 1449 | |
Front Panel |
| |
Outlet | Single 30A, | |
AC Mains Circuit Breaker | 30A Resettable | |
Indicators | Active (Green), Fault (Red), Incoming AC (Red) | |
External Trigger/Manual On | Slide Switch | |
Connectors | 5 Position Phoenix Euro Block Style | |
Hard Switch Remote Trigger | SPST Contact | |
Status Signals | Output for Voltage (When used with | |
AC Mains Interconnect | Screw Terminal Block | |
Technical Data |
| |
Current Rating | 30A | |
Operating Voltage | 102VAC - 132VAC | |
Power Consumption | 500 milliwatts | |
Power Requirements | 120V 60Hz | |
Extreme Voltage Shutdown | (EVS) Below 102V or above 132V AC Line (When used with | |
DCV Remote Trigger | ||
High Voltage Surge Protection | Trigger at 133VAC, 1ms typically (When used with | |
Low Voltage Surge Protection | Trigger at 101VAC, 1ms typically (When used with | |
Spike and Surge Suppression | Hot to Neutral, Hot to Ground, Neutral to Ground | |
Spike Protection Modes | Circuitry on Incoming AC Mains | |
Min. Spike Clamping Voltage | 460 VRMS @ 3,000 amps | |
Max. Spike Clamping Voltage | 6kV | |
Max. Spike Clamping Resp. Time | <1 nanosecond | |
Spike Clamping Voltage @ 100A | 1,250Vp for 20µs | |
Maximum Surge Current | 6,500A | |
Energy Rating | 600 Joules | |
Temperature Range | 5° – 35°C | |
Humidity Range | 5% to 95% R.H. | |
Mechanical |
| |
Chassis Finish | Black | |
Mounting | #8 5⁄16" Self Tapping Screws | |
Height | 3" (76.2mm) | |
Width | 3.5" (88.9mm) | |
Length | 8.5" (215.9mm) | |
Weight | 1.25 lbs (0.68kg) |
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 19 – | AtlasSound.com |
Specifications are subject to change without notice.