Cisco Systems RPS 675 manual Statement 100C

Page 50

Connecting the RPS 675

Figure 2-6 Connecting the Cable to the RPS 675

100-240V~

12V

 

 

 

10-6A

/25A, -48V

 

50/60Hz

 

/7.8A MAX

 

 

 

 

OUTPUT

 

 

DC

OUTPUT 1

 

 

 

DC

OUTPUT 2

CAUTION: RPS

NOT HOT

PLUGGABLE

 

 

 

DC

OUTPUT 3

 

 

 

 

 

 

 

 

DC

 

 

 

 

OUTPUT 4

DC OUTPUT 5

DC OUTPUT 6

Chapter 2 Installation

86669

Warning Attach only the Cisco RPS (model PWR675-AC-RPS-N1) to the RPS receptacle.

Statement 100C

Step 3 Connect the other end of the RPS connector cable to the RPS receptacle on the switch.

Step 4 Repeat Step 2 through Step 3 for each switch that the RPS 675 will support. Step 5 Connect all supported devices to an AC power source.

Note The RPS 675 is designed to provide backup for internal power supply failures of connected device power supplies. It is not designed to act as a backup power source that protects against losses of power due to external power outages. We recommend using an uninterruptable power system (UPS) as protection against power outages.

Step 6 If the RPS is not already connected to AC power, connect the AC power cable to the RPS 675 as shown in Figure 2-7, and connect the other end of the power cable to an AC power source.

 

Cisco RPS 675 Redundant Power System Hardware Installation Guide

2-16

78-15201-04

Image 50
Contents February Page Page Page N T E N T S Contents Vii Viii Cisco Limited Lifetime Hardware Warranty Terms Duration of Hardware Warranty Cisco Limited Lifetime Hardware Warranty Terms Xii Audience PurposeOrganization ConventionsStatement 1071-Warning Definition Conservez CES Informations TA Vare PÅ Disse Instruksjonene Spara Dessa Anvisningar Xix GEM Disse Anvisninger Xxi Xxii Related Publications XxiiiObtaining Documentation and Submitting a Service Request Product Overview Features Front-Panel Description LEDsOutput LED Standby/Active Button Standby/Active Button Rear-Panel Description RPS 675 Rear PanelDeployment Strategies RPS 675 Supporting One-to-One Redundancy Installation Preparing for InstallationInstallation Preparing for Installation Installation Preparing for Installation EMC Regulatory Statements Installation Preparing for Installation Statement 256-Class a Warning for Hungary Site Requirements Installing the Switch Table or Shelf-MountingRack-Mounting Tools and Equipment Required Phillips flat-head screws Attaching Brackets for 19-Inch Racks Rear Panel Forward Attaching Brackets for 24-Inch Racks Rear Panel Forward Connecting the RPS Mounting the RPS in a RackInstallation Connecting the RPS Statement 100C Connecting the AC Cable to the RPS Installation Connecting the RPS Troubleshooting Troubleshooting Technical Specifications EMC Connector and Cable Specifications Pin Designation Translated Safety Warnings Statement 17B-Overtemperature Warning 78-15201-04 78-15201-04 Statement 43-Jewelry Removal Warning 78-15201-04 Statement 48-Stacking the Chassis Warning 78-15201-04 Appendix C Translated Safety Warnings Statement 265-Redundant Power Supply Connection Warning 78-15201-04 Statement 1001-Work During Lightning Activity Statement 1004-Installation Instructions 78-15201-04 Appendix C Translated Safety Warnings 78-15201-04 Appendix C Translated Safety Warnings 78-15201-04 78-15201-04 78-15201-04 Appendix C Translated Safety Warnings 78-15201-04 Appendix C Translated Safety Warnings 78-15201-04 Statement 1017-Restricted Area 78-15201-04 78-15201-04 Statement 1019-Main Disconnecting Device 78-15201-04 Statement 1024-Ground Conductor 78-15201-04 78-15201-04 78-15201-04 Statement 1030-Equipment Installation 78-15201-04 Statement 1040-Product Disposal 78-15201-04 Statement 1073-No User-Serviceable Parts 78-15201-04 78-15201-04 78-15201-04 78-15201-04 Numerics IN-2 IN-3 IN-4

RPS 675 specifications

The Cisco Systems RPS 675, or Redundant Power System 675, is a high-performance power supply solution designed to enhance the reliability and availability of network equipment in critical data center environments. This redundant power system supports the continuous operation of Cisco switches, routers, and other devices, ensuring that organizations can maintain their network uptime even in the event of a power failure or disruption.

One of the standout features of the RPS 675 is its ability to provide backup power to multiple Cisco devices. It can be connected to up to six compatible devices simultaneously, offering flexibility and scalability for various network architectures. This centralized power management not only reduces the need for multiple power sources but also simplifies the deployment of backup power solutions across the network.

In terms of technology, the RPS 675 incorporates advanced power management capabilities. It features an intelligent power distribution system, which optimally allocates power based on the requirements of connected devices. This ensures that critical devices receive the necessary power without overloading the system, enhancing overall energy efficiency. The system supports a wide range of input voltage options, making it suitable for various environments worldwide.

Another key characteristic of the RPS 675 is its compact design. The unit is engineered to fit into standard 19-inch racks, making it suitable for installation in both small and large data center environments. Its modular design allows for easy expansion and maintenance, ensuring that organizations can adapt their power needs as they grow.

The RPS 675 also boasts robust monitoring and management features. It includes an integrated web interface that provides real-time visibility into the power status of connected devices, as well as alerts for any potential issues. This proactive monitoring capability allows IT administrators to quickly identify and address power-related problems before they lead to network outages.

Overall, the Cisco Systems RPS 675 is an essential component for organizations requiring reliable and efficient power solutions for their networking equipment. With its multiple-device support, intelligent power management, compact design, and robust monitoring features, it stands out as a strategic investment for enhancing network resilience and operational continuity in today’s increasingly digital landscape.