Royal Consumer Information Products G20 manual Installation Regulations and Requirements

Page 10

INSTALLATION REGULATIONS AND REQUIREMENTS

In the interests of both the Law and of Safety, this appliance must only be installed by a competent person in accordance with the current Gas Safety (Installation and Use) Regulations or the rules in force and the manufacturer’s instructions. Note: Failure to install a gas appliance correctly could lead to prosecution.

The following are the relevant Codes of Practice and British Standards.

The Building Regulations issued by the Department of the Environment.

The Building Standards (Scotland)(Consolidation) Regulations issued by the Scottish Development Department.

BS 83O3 1986

BS 544O Pt1 199O

BS 544O Pt2 1989

BS 1251 1987

BS 5871 Pt2 1991

 

BS 7566 Pt 1-4 1992

BS 6891 1988

BS 6461 Pt1

1984

 

 

BS 715 1993

BS 1289 Pt1

1986

& 1975

 

FIRE SURROUND AND OPENING REQUIREMENTS

Check that the chimney and flue structure are sound and conform to the following flue requirements:

a)A conventional brick or stone chimney with a minimum effective cross-sectional dimension of 228mm x 228mm, a lined flue with a minimum diameter of 175mm, a minimum effective height of 3m and having a chairbrick and throat forming lintel conforming to BS 1251 or a builders opening measuring 540mm high x 400mm wide with a sufficient volume for debris collection. If a chairbrick is fitted, a minimum depth requirement for the fire with the spacer fitted is shown in fig 1 - if insufficient space is available the chairbrick will have to be removed.

b)A twin walled metal flue box manufactured to BS 715 with a 125mm diameter insulated flue with a minimum effective height of 3 metres. See page 6.

c)A pre-cast flue conforming to the requirements of BS 1289 Pt 1 1986 including properly constructed pre-cast flues (formerly BS 1289 1975) with a cross sectional area of 13000sq mm.

Dampers, register plates or incorrect flue terminals, must not restrict any of the above flues. The flue must only service a single appliance and not have any branches or traps which may impede the natural draught, any flue damper or restrictor must be removed or fixed in the fully open position.

The front and base of the fire opening must be flat and square to ensure a good seal with the appliance; this is to ensure that there is no reduction in draught that may cause spillage to occur.

CONTENTS CHECK LIST

Fire Box Assembly c/w

Burner Assembly

Glass Panel

Flue Restrictor

Blanking Plate & Gasket

Ceramic Components Fibre Back panel

L & R Hand Side Cheeks Simulated Coal front Coal Support Shelf

10 Large Coals

3 Small Coals

Components

Fender

Ash Pan Cover

L & R Hand Side Covers

Canopy

Spacer Frame

Fixing Kit

6 Plastic Wall Plugs

4 No 10 x 1 1/4" Round Hd Woodscrews

4 U-Spring Clips

2 No 8 x 1" Round Hd Woodscrews

2 No 8 x 1/2" Self Tap Screws

2 Penny Washers

4 M4 x 12 Pan Hd Machine Screws

1 8mm Equal End Coupling

2 M4 Wing Screws

1 Cable Fixing Kit

Bundy Pipe for Concealed Fitting Bundy Pipe for RH Gas Supply 8mm x 8mm Inline Connector Installation & Servicing Instructions Users Instructions

Brass Knob Kit

Page 3

Image 10
Contents 52$/&+/71+$0 Description Important NotesLocation of Combustible Shelves Above Fire Side of Fire Technical DataTo Light Appliance see Fig Dismantling the Fire BED for Cleaning see , 4 Coal Laying Instructions Spares and Service Cleaning the Front of the Appliance and Cleaning the WindowShort Parts List Registration Record Installation and Servicing Instructions Description Contents Check List Installation Regulations and RequirementsFire Surround and Opening Requirements Page Page Installation Using a 5 Diameter Metal Flue BOX Important The Flue restrictor plate must be removed see FigInstalling the Appliance in Position Installation of the ApplianceDismantling the Appliance Prior to Installation Option aOption b Laying the Fire BEDPage Page Page Page Page Spillage Check Checking Operation of FireAdvise That Maintenance and Servicing General Removal of Debris or Soot DepositPage Description