Royal Consumer Information Products G20 manual Spares and Service, Short Parts List

Page 6

Note: Should any ‘coals’ or the coal bed become damaged, lost or broken, only the correct replacements must be obtained and fitted before the appliance is used. Extra ‘coals’ etc. must not be added to the coal bed. The coal bed must always be assembled as detailed.

This appliance is fitted with an Oxy/pilot the purpose of which is to monitor spillage in the event of a flue blockage or hazardous flue condition. This may cause the oxygen content of the room to become depleted; the flame then becomes extended which allows the thermocouple to cool sufficient to cause the FFD to cut off the supply of gas to the burner. If this occurrence is repeated, the appliance must not be used until a specialist has been consulted.

CLEANING THE FRONT OF THE APPLIANCE AND CLEANING THE WINDOW

The fire must be turned off and allowed to cool for approximately 2 hours. The paintwork should be cleaned with a soft cloth or soapy water. The brass trim can be cleaned with most proprietary brands of metal cleaners although care must be taken not to use abrasive materials. The glass window can be cleaned with most proprietary window cleaners.

To clean the coal bed or the inside of the glass panel refer to 5.1 & 5.2

SPARES AND SERVICE

For spares and service, apply to your local Supplier, Installer or direct to the manufacturer, stating that the appliance is a Royal Cheltenhan. Quote the GC Appliance Number and the Serial Number from the Data Badge located on the front control panel.

Advantage should be taken of regular servicing and inspection of gas appliances to ensure their continued safe operation.

SHORT PARTS LIST

Description

Qty

Crosslee Pt No

GC No

Complete coal & fibre pack

1

 

42203

 

 

 

 

 

 

 

 

 

 

 

Page 6

Image 6
Contents 52$/&+/71+$0 Description Important NotesTechnical Data Location of Combustible Shelves Above Fire Side of FireTo Light Appliance see Fig Dismantling the Fire BED for Cleaning see , 4 Coal Laying Instructions Cleaning the Front of the Appliance and Cleaning the Window Spares and ServiceShort Parts List Registration Record Installation and Servicing Instructions Description Installation Regulations and Requirements Contents Check ListFire Surround and Opening Requirements Page Page Installation Using a 5 Diameter Metal Flue BOX Important The Flue restrictor plate must be removed see FigInstalling the Appliance in Position Installation of the ApplianceDismantling the Appliance Prior to Installation Option aOption b Laying the Fire BEDPage Page Page Page Page Checking Operation of Fire Spillage CheckAdvise That Maintenance and Servicing General Removal of Debris or Soot DepositPage Description