INSTALLATION INSTRUCTIONS

THE FOLLOWING SECTION LISTS THE INSTALLATION REQUIREMENTS AND REGULATIONS

A competent person in accordance with the current Gas Safety (Installation and Use) Regulations or the rules in force and in accordance with the manufacturer’s instructions must install the appliance; failure to do so could lead to prosecution.

The following are the relevant Codes of Practice and British Standards.

The Building Regulations issued by the Department of the Environment. The Building Standards (Scotland) (Consolidation) Regulations issued by the Scottish Development Department.

BS 8303

Pt 2 1994

BS 5440 Pt. 1 1990 & Pt. 2 1989

BS 1251

1987

BS 5871 Pt. 2 1991 & Pt. 3 1991

BS 6891

1988

BS 6461 Pt. 1 1984

BS 715 1993

BS 1289 Pt. 1 1986

BS 7566 Pts. 1-4 1992

 

Technical Data

 

Overall height of fire with spacer

= 612mm

Overall height of fire without spacer

= 605mm

Minimum height of opening required

= 540mm

Maximum height of opening with spacer

= 590mm

Maximum width of opening required

= 405mm

Maximum width of opening with spacer

= 470mm

Forward projection from opening

= 60mm

(without front and fret)

 

Forward projection from opening with

= 105mm

spacer (without front and fret)

 

Depth behind opening without spacer

= 190mm

Depth behind opening with spacer

= 145mm

(See page 18 for diagram)

 

TYPE OF GAS G20 only

 

Supply Pressure 20 mbar +/- 1 mbar (Cold)

 

GAS INPUTS

 

Max 6.6 kW (22520 Btu/h)

 

Min 3.6 kW (12300 Btu/h)

 

Pilot 0.26 kW (890 Btu/h)

 

Main Injector Type

 

Stereomatic

046/19/196/74M

Gas valve

Concentric TESA 3058/S

Pilot

OP Oxy-Pilot NG 9022

GAS CONNECTION

8MM OD Tube

WEIGHT

 

12.5 kg (without front and fret)

 

Page 4

Image 4
Contents Class 2 Flame System Description Important NotesClearance to Side Timber Surrounds etc Coal Layout See Figs 6 9 6 Large and 12 smallClearance to Shelves Installation Instructions Technical DataInstalling the Appliance Installation of the Appliance Installation using a 5 Diameter Metal Flue BoxDismantling the fire Prior to Installing Installing the Appliance in Position Vent Box Installed with Spacer frameCoal Layout See Figs 6 Spillage Check Checking Operation of FireAdvise that Short Parts List Turn OFF the GAS Supply to the AppliancePage Page Page Page Page Page