| Venting Installation |
|
| instructions | Minimum Pipe |
| Continued | |
7. | Overlap 11/4" | |
Combustible Exterior Wall Only: Slide the wall firestop over |
| |
| the vent pipe before connecting horizontal run to vent cap (see |
|
8. | Figure 12). | Direct Vent |
Carefully move fireplace, with vent assembly attached, toward | Pipe | |
| wall and insert vent pipe into horizontal termination. The pipe | Wall |
9. | overlap should be a minimum of 11/4". | Firestop |
Combustible Exterior Wall Only: Slide wall firestop against |
| |
| interior wall surface and attach with screws provided. See |
|
| Figure 13 for horizontal termination details. |
|
10. | Place fireplace into position and shim with noncombustible |
|
| material if needed. Nail or screw side flanges to framing to |
|
| secure unit in place. IMPORTANT: Make sure fireplace is |
|
| level before securing. If fireplace is not level it will not work |
|
| properly. | Maintain 1" |
|
| Minimum Air |
|
| Space Around |
|
| Outer Pipe When |
|
| Penetrating a Wall |
| Cut Siding Away |
|
| to Fit Standoff | 10 3/4" x 10 3/4" |
| Standoff | Framed Opening |
|
| |
| Wood Screw |
|
| Vent Cap |
|
Siding Standoff
Screws
High Wind
Termination
Apply Mastic to
Outside Edge of
Standoff
Exterior Wall with Vinyl Siding
| Figure 13 - Typical Horizontal Termination Cap Mounting with |
Screws | Additional Siding Standoff Installed |
Apply Mastic to
All Four Sides
Figure 11 - Installing Siding Standoff
(Combustible Exterior)
Interior Wall
Surface
Wall
Firestop
Vent Cap | Horizontal | |
(Horizontal | ||
Vent Pipe | ||
Termination) | ||
|
Screw
Figure 12 - Connecting Vent Cap with Horizontal Vent Pipe
www.desatech.com |