Desa GL36CRP, GL36CLP installation manual Introduction, Selecting Location, Before YOU Begin

Page 5

Introduction

Models (V)GL36CR(P)/CL(P) are decorative gas fireplaces that use a millivolt gas control valve with millivolt ignition system. Models (V)GL36CR(P)E/CL(P)E use an electronic gas control valve with electronic ignition system.

These systems require a 6" B-type vent that is not supplied by DESA. For installation guidelines, check your B-vent instructions.

WARNING: This gas appli- ance must not be connected to a chimney flue servicing a solid fuel burning appliance.

If you are uncertain as to what gas your unit is approved and tested for, check rating plate on inside of fireplace opening or consult your local distributor of DESA products.

BEFORE YOU BEGIN

Before beginning the installation of your appli- ance, read these instructions through completely. This DESA appliance and its approved compo- nents are safe when installed according to this installation manual and are operated as recom- mended by DESA. Unless you use DESA approved components tested for this appliance, YOU MAY

CAUSE A FIRE HAZARD!

The DESA warranty will be voided by and DESA dis- claims any responsibility for the following actions :

A)Modification of the appliance or any of the components manufactured by DESA unless otherwise permitted by DESA.

B)Use of any component part not approved by DESA in combination with this appliance.

C)Installation and/or operation in a manner other than instructed in this manual.

D)The burning of anything other than the type of gas approved for use in this gas appliance.

This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electri- cal Code, ANSI/NFPA 70-1987and the CSA C22.1 Canadian Electrical Code for Canada.

The installation must conform with local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/NFPA 54 or with the current CAN/CGA B149 Installation Codes for Canada.

This appliance complies with ANSI Z21.50B- 1990 and CAN/CGA-2.22-M89as a Vented Gas Appliance and is listed and tested by the Omni Test Laboratories.

WARNING: Installation and repair should be done by a quali- fiedserviceperson. Theappliance should be inspected before use and at least annually thereafter by a qualified service person. More frequent cleaning may be required due to excessive lint from carpet- ing, bedding etc. It is important that the control compartments, burnersandcirculatingairsystems be kept clean.

NOTICE: This appliance is not intended to be used as a primary source of heat.

Selecting Location

To determine the safest and most efficient location for your appliance, you must take into consider- ation the following guidelines:

1.The location must allow for proper clearances (see Clearances, page 6).

2.The location should be in a place where drafts, air conditioning ducts, windows or doors will not affect fireplace heat output.

3.A location that avoids the cutting of joists or roof rafters will make installation easier. Figure 2 shows a typical two-sided fireplace installation.

Existing

Side

Wall

4" From Opening to Perpendicular Wall

Access Control Panel

Figure 2 - Typical Two Sided Fireplace

Installation

112301-01Dwww.desatech.com

Image 5
Contents For Your Safety Table of Contents High traffic areas Windy or drafty areas Fireplace Dimensions DimensionsBefore YOU Begin IntroductionSelecting Location Mantel Clearances Fireplace InstallationClearances Framing Vent pipe installationOptional Outside air Kit Model ak-4 Wall Switch InstallationGAS Supply Testing ON/OFF GAS Line HOOK-UPFireplace Facing Glass DoorOperating Fireplace For Your Safety Read Before LightingMillivolt models Lighting InstructionsElectronic models To Turn OFF GAS To ApplianceInspecting Burner Pilot Assembly AdjustmentBurner Flame Adjustment Technical Service Cleaning MaintenanceWiring Diagrams SpecificationsMillivolt system TroubleshootingObserved Problem Possible Cause Remedy Electronic ignition system Tion see Wiring DiagramsReplacement Parts and Accessories 112301-01D Remedy and Exclusions Limited Warranty

GL36CRP, GL36CL, GL36CR, GL36CLP specifications

The Desa GL36CL, GL36CRP, GL36CLP, and GL36CR are innovative models in the field of space heating and fireplace technology. These units are designed to provide warmth and ambiance while ensuring energy efficiency and modern aesthetics.

The GL36CL model is characterized by its clean lines and contemporary design, making it an excellent choice for urban environments. Engineered with advanced gas-burning technology, it provides a powerful heating output while minimizing emissions, offering an eco-friendly solution for home heating. The unit features a sleek glass front that enhances the viewing experience of the flames, creating an inviting atmosphere in any room.

The GL36CRP model, on the other hand, is built with versatility in mind. Its ceramic log set is designed to replicate the look of real wood burning, offering an authentic fireplace ambiance without the hassle of traditional wood burning. The adjustable flame height settings allow users to customize their heating needs and visual appeal. Additionally, the remote control feature enables convenient operation, making it easy to adjust the settings from anywhere in the room.

Next, the GL36CLP model combines modern technology with user-friendly features. It is equipped with a built-in thermostat and programmable timer, allowing homeowners to set their heating schedule according to their preferences. This ensures optimal comfort while saving on energy costs. The glass front also contributes to enhanced safety, preventing accidental contact with the flames while providing a clear view of the flickering fire.

Lastly, the GL36CR model emphasizes efficiency and reliability. Its high-efficiency rating ensures that it effectively converts gas into heat, resulting in reduced energy consumption. This model is compatible with various home decor styles, thanks to its customizable finishing options. The easy installation process further adds to its appeal, allowing for quick setup in any residential space.

In summary, the Desa GL36 series models—GL36CL, GL36CRP, GL36CLP, and GL36CR—are exceptional choices for anyone looking to enhance their home's heating system. With a combination of advanced technology, energy efficiency, and stylish designs, these models cater to a variety of needs and preferences, making them ideal for contemporary living spaces.