INTRODUCTION
NO COMPONENT OF THIS FIRE IS MANUFACTURED FROM ASBESTOS OR ASBESTOS RELATED PRODUCTS.
The ATHENA L.F. is an open fronted inset live coal effect gas fire specially designed for
GENERAL INSTALLATION REQUIREMENTS
In your own interest and that of safety, it is the law that all gas appliances are installed by competent persons in accordance with the current Gas Safety (Installation and Use) Regulations. Failure to install appliances correctly could lead to prosecution.
The installation MUST be in accordance with these installation instructions, all the relevant parts of the Local and National Building Regulations or Building Standards (Scotland) (Consolidation) Regulations and the relevant recommendations of the current editions of the following British Standards:
B.S. 5871 : Part 2
B.S. 5440 : Parts 1 & 2
B.S. 6891
B.S. 6461 : Parts 1 & 2
B.S. 715
B.S. 1251
B.S. 1289 : 1975
B.S. 1289 : Part 1 : 1986
B.S. 1289 : Part 2 : 1989
Any other relevant British Standard Code of Practice and/or Local Building Regulations and in accordance with the rules in force.
1.0 TECHNICAL DATA
1.1 DIMENSIONS |
|
(Overall) | mm |
Height | 682 |
Width | 635 |
Depth | 115 |
Forward Projection | 100 |
Height to top of flue aperture | 529 |
Weight | 18 Kg |
1.2INPUTS AND PRESSURES
Maximum Heat Input (Gross) | 6.0 kW | 20470 Btu/h |
Minimum Heat Input (Gross) | 2.3 kW | 7848 Btu/h |
Supply Pressure | 20.0 mbar |
|
Setting Pressure Cold | 13.0 mbar ± 1mbar | |
Gas Rate Adjustment | NONE |
|
1.3BURNER AND CONTROL DETAILS
Main Burner | ÿ 992174 |
Pilot Burner | SIT OP 9063 |
Injector (Main Burner) | Bray Cat 82/440 |
Ignition | Battery Operated Electronic Ignition. Battery Size 9V MN1604 or 6LR61 |
Control Tap | Concentric (with FSD) Model Number TESA |
Spark Gap | 3.0mm to 5.0mm |
Control Knob Settings | OFF, HIGH, MED, ECON, PILOT |