5.0 INSTRUCT USER

Refer to Users Instructions

Make sure the user understands the following:

(a)How to light and operate the fire.

(b)The fire can be lit with a match or taper in the event of failure of the battery ignition.

(c)Demonstrate the removal and replacement of the coals. Advise on the need to clean these regularly.

(d)Advise that for safe and efficient operation, the fire should be serviced annually by British Gas or a CORGI registered service agent.

(e)Explain to the user the functioning of the combined flame supervision and atmosphere monitoring device as detailed in Section 6.4. Stress that if this device repeatedly shuts off the fire, the fault must be rectified immediately by a competent person.

(f)When the fire is first lit a slight smell and light smoke may be noticed but this will clear away with a few hours of use on HIGH.

(g)Advise the user to carefully clean the base of the fire with a vacuum cleaner regularly.

Hand over the Users Instructions

6.0 SERVICING INSTRUCTIONS

IMPORTANT NOTES

1.Turn off the gas supply to the fire before starting any servicing.

2.Always test for gas soundness after servicing or exchanging any component.

3.Remove the fire from the surround and inspect the catchment space for build up of debris on every service visit.

4.Check the fire for clearance of products on every service visit.

5.Remove any lint from the top of the main burner and from around the aeration hole of the pilot and main burner.

6.1REMOVE BURNER TRAY

1.Remove the outer case by lifting it upwards and away from the fire.

2.Remove the loose coals and coal bed.

3.Disconnect the gas supply at the inlet to the fire.

4.Remove the screw from the slider valve connection to the linkage.

5.Separate the yellow wires on the thermocouple break micro switch from the white wires attached to the pilot assembly.

6.Disconnect the red and blue wires from the ignition unit.

7.Remove the two screws securing the burner tray to the firebox and slide out the burner tray.

6.2BURNER INJECTOR

1.Remove the burner tray (Section 6.1 above).

2.Undo the union nuts on the burner gas inlet and at the gas valve end and remove the gas pipe.

3.Undo the two screws securing the injector bracket to the burner manifold.

4.Undo the nut securing the injector to its holder, and remove the injector and washer.

5.Replace with the new injector.

6.Re-assemble in the reverse manner.

6.3GAS VALVE / FSD ASSEMBLY

1.Remove burner tray (Section 6.1 above)..

2.Turn the tray upside down.

3.Undo the gas connections to the gas valve.

4.Release the thermocouple nut and ease out the probe.

5.Undo the two screws securing the burner to its tray and ease out the gas valve and gas inlet pipe.

6.Remove the two screws securing the gas valve to its bracket and remove the gas valve.

7.Replace with the new gas valve/fsd assembly.

8.Re-assemble in the reverse manner.

13

Image 13
Contents For USE with Natural GAS only Athena LF Athena LFContents Layout Technical Data General Installation RequirementsIntroduction Conditions of Installation Check the Flue for Good Draught AS Detailed in Section PRE-CAST Flue of Minimum Size FigFreestanding GAS Flue BOX Selkirk Code Metal Flue BOX/125mm Diameter Flues Figs a and 3BInstallation of Fire Important Notes Method of InstallationFixing by Tension Cable FIT Mounting EYE ScrewsGAS Connection Fixing Directly to Surround FaceConcealed Connection Front ConnectionCommissioning Install Fuel Effect ComponentsFIT Outer Case Check GAS PressureCheck Ignition Test for SpillageCheck Operation of FSD Servicing Instructions Instruct UserIgnition Battery Replacement Pilot AssemblyFuel Effect Components Main BurnerIgnition Micro Switch Hints on Fault FindingThermocouple Break Micro Switch Description Short List Parts