Installation Requirements

VGBQ410-3RT/E*

VGBQ412-2RT/E*

VGIQ410-3RT/E*

VGIQ412-2RT*

T-Series/E-Series

T-Series/E-Series

T-Series /E-Series

T-Series Two-Burner Grill

Three-Burner All-Grill

Two-Burner Grill

Three-Burner All-Grill

w/Side Burners

 

w/Side Burners

(inc. TruSear™ Burner)

(inc. TruSear™ Burner)

 

 

UTILITY

 

REQUIREMENTS

GAS

Fixed piping installations

Check with local gas utility company or with local codes for instructions on installing gas supply lines. All gas connections should be made by a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation must comply with the National Fuel Gas Code ANSI Z223.1.

An installer-supplied gas shut- off valve must be installed in an easily accessible location. All installer-supplied parts must conform to local codes.

Must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that system at test pressures equal to or less than 1/2 psi (3.5 kPa).

Natural gas models

Water column pressure

o Operating pressure—4.0"

WCP

o Supply pressure of 6" – 14"

WCP

o If incoming pressure exceeds 14" WCP,a step-down regulator is required.

Accepts standard residential 1/2” (1.3 cm) ID gas service line; 1/2” (1.3 cm) NPT male with 7/8” (2.2 cm) flare adapter. o If using a Viking GSH12

flexible hose, remove the 1/2” (1.3 cm) flare adapter and attach hose to the 7/8” (2.2 cm) male flare on the regulator assembly.

LP/propane models

Water column pressure

o Operating pressure—10” WCP o Supply pressure of 11” – 14”

WCP (for fixed piping installations)

o If incoming pressure exceeds 14” WCP,a step-down regulator is required.

Accepts standard residential 1/2” (1.3 cm) ID gas service line; 1/2” (1.3 cm) NPT male with 3/8” (0.95) flare adapter.

LP/propane tank installations

Water column pressure

o Operating pressure—10”

WCP

Includes high-capacity hose/regulator assembly for connection to a standard 5- gal./20-lb. (approx. 12” diameter/18”H.) LP/propane gas cylinder equipped with a Type 1, QCC-1 connector

o The cylinder connection device must be compatible with the Type 1, QCC-1 connector on the outdoor cooking appliance.

o The cylinder must be provided with a shut-off valve terminating in an LP/propane gas supply cylinder valve outlet specified.

o The cylinder supply system must be arranged for vapor withdrawal and provided with a listed OPD (overfilling prevention device).

ELECTRICAL

T-Series models

o 9-volt DC battery for electronic ignition

o 2’ (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor.

120 VAC/60 Hz

o Rotisserie motor max. amp usage—6.0

E-Series models

o 3’ (91.4 cm) power cord supply cord with 3-prong grounded plug attached to grill

120 VAC/60 Hz

o 120 VAC/60 Hz

o Grill max. amp usage

VGBQ/VGIQ410—2.2

VGBQ/VGIQ412—2.3 o 2’ (61.0 cm) power cord

supply cord with 3-prong grounded plug attached to rotisserie motor.

120 VAC/60 Hz

o Rotisserie motor max. amp usage—6.0

PLUMBING

Not applicable

 

VGBQ410-3RT

VGBQ412-2RT/E

VGIQ410-3RT/E

VGIQ412-2RT

Burner rating

 

 

 

 

Standard SS grill burners (each)

 

25,000 BTU (7.3 kW) Nat./22,500 BTU (6.5 kW) LP

 

Smoker burner (split standard)

 

12,500 BTU (3.7 kW) Nat./10,500 BTU (3.1 kW) LP

 

GourmetGlo™ rotisserie burner

 

15,000 BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP

 

Side grill burners (each)

 

15,000 BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP

 

TruSear infrared burner

30,000 BTU (8.8 kW) Nat./LP

 

30,000 BTU (8.8 kW) Nat./LP

 

PLANNING AND DESIGN GUIDE

R EL EA S E D 0 5/ 1 2 / 0 8

VI KIN GRA NGE .COM

• 1 -888 -V IK ING 1

© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE

Image 6
Contents All models include Standard Features & AccessoriesModel Options VGBQ410 modelsVGIQ410 models VGIQ412 models Series onlyDimensions & Specifications Product DimensionsClearance Dimensions & Hood Swing Planning Design GuideInstallation Requirements Gas Inlet and Power Cord Location AreaUtility Installation Notes & Accessories Rotisserie Baskets SS Grill GratesWarming Racks Compliance Information

VGIQ410-3RT/E*, VGIQ412-2RT*, VGBQ412-2RT/E*, VGBQ410-3RT/E* specifications

The Viking range of industrial valves includes models such as the VGBQ410-3RT/E*, VGBQ412-2RT/E*, VGIQ412-2RT*, and VGIQ410-3RT/E*. These valves are known for their robust design and reliability, making them ideal for a variety of demanding applications in sectors such as HVAC, automotive, and process industries.

One of the standout features of the Viking VGBQ models is their ability to efficiently handle both hot and cold water systems. The valves are designed with precision-engineered components that ensure a tight seal, preventing leaks while maintaining optimal flow rates. This characteristic is crucial in industrial settings where even minor leaks can lead to significant operational inefficiencies and increased costs.

The VGIQ series, on the other hand, incorporates advanced technologies into its design. These valves are equipped with integrated actuators that provide precise control over fluid flow. The electronic controls allow for automated operation, which enhances the efficiency of the systems in which these valves are installed. The actuators are designed to be responsive and can accommodate variable flow rates, making them highly adaptable to changing operational conditions.

All models feature durable construction materials, including corrosion-resistant alloys that ensure longevity even in harsh environments. This durability reduces the need for frequent maintenance and replacements, providing long-term cost savings for users. Additionally, the Viking valves are designed for easy installation, which minimizes downtime during setup and reduces overall labor costs.

In terms of safety, these valves come with built-in mechanisms that provide fail-safe operations. In the event of a power failure or other malfunctions, the valves automatically revert to a preset position, preventing uncontrolled flow that could compromise system integrity.

Another significant characteristic of these Viking valves is their versatility. They can be employed in a range of applications, from managing water supply systems to playing critical roles in heating and cooling processes. Their compatibility with various control systems further enhances their usability across different platforms.

Overall, the Viking VGBQ410-3RT/E*, VGBQ412-2RT/E*, VGIQ412-2RT*, and VGIQ410-3RT/E* valves represent an excellent combination of efficiency, durability, and technology. With their advanced features and robust design, they are well-suited for modern industrial applications, ensuring reliable performance and operational efficiency.