Nortel Networks 4050 manual About alarm messages, Lists the System Control Process Info messages

Models: 4050

1 922
Download 922 pages 38.09 Kb
Page 854
Image 854

854Appendix B Syslog messages

Table 191 lists the System Control Process INFO messages.

Table 191 System control process messages — INFO

Message

Category

Explanation/Action

 

 

 

System started [isdssl-<version>]

INFO

Sent whenever the system control process has been

 

 

(re)started.

 

 

 

About alarm messages

Alarms are sent at a syslog level corresponding to the alarm severity shown in Table 192.

Table 192 Alarm severity and syslog level correspondence

Alarm severity

Syslog level

 

 

CRITICAL

ALERT

 

 

MAJOR

CRITICAL

 

 

MINOR

ERROR

 

 

WARNING

WARNING

 

 

*

ERROR

 

 

Alarms are formatted according to the following pattern:

Id: <alarm sequence number>

Severity: <severity>

Name: <name of alarm>

Time. <date and time of the alarm>

Sender: <sender, e.g. system or the Nortel SNAS 4050 device’s IP address>

Cause: <cause of the alarm>

Extra: <additional information about the alarm>

When an alarm is cleared, one of the following messages is sent:

Alarm Cleared Name=“<Name>” Id= “<ID>” Sender=“<Sender>”

Alarm Cleared Id=“<ID>”

320818-A

Page 854
Image 854