90Chapter 3 Managing the network access devices

The HealthCheck menu includes the following options:

/cfg/domain #/switch #/hlthchk followed by:

interval <interval> Sets the time interval between checks for switch activity.

interval is an integer that indicates the time interval in seconds (s), minutes (m), or hours (h). The valid range is 60s (1m) to 64800s (18h). The default is 1m (1 minute).

deadcnt <count>

Specifies the number of times the Nortel SNAS 4050

 

will repeat the check for switch activity when no

 

heartbeat is detected.

 

count is an integer in the range 1–65535 that

 

indicates the number of retries. The default is 3.

 

If no heartbeat is detected after the specified number of

 

retries, the Nortel SNAS 4050 enters status-quo mode.

 

 

sq-int <interval>

Sets the time interval for status-quo mode, after which

 

the network access device moves all clients into the

 

Red VLAN.

 

interval is an integer that indicates the time

 

interval in seconds (s), minutes (m), or hours (h).

 

The valid range is 0 to 64800s (18h). The default is

 

1m (1 minute).

Controlling communication with the network access devices using the CLI

To stop communication between the Nortel SNAS 4050 and a network access device, use the following command:

/cfg/domain #/switch #/dis

Enter apply to apply the change immediately.

Note: If the switch is not going to be used in the Nortel SNA network, Nortel recommends deleting the switch from the Nortel SNAS 4050 domain, rather than just disabling it.

320818-A

Page 90