Chapter 10 Configuring system settings 513

 

 

 

 

Table 100 Interface fields (continued)

 

 

 

 

Field

Description

 

 

 

 

Mode

Specifies the mode of operation for the port numbers

 

 

assigned to this interface. The options are:

 

 

• failover — only one link is active at any given time. If the

 

 

port with an active link fails, the active link is

 

 

immediately switched over to one of the other ports

 

 

configured for the interface. When you select failover

 

 

mode, you also have the option of specifying a primary

 

 

port.

 

 

• trunking — active links are sustained on all configured

 

 

ports simultaneously, in order to increase network

 

 

throughput.

 

 

The default is failover.

 

 

 

 

Primary Port

Specifies the primary port in the interface, on which the

 

 

active link is set up. If the primary port fails, the active link

 

 

is immediately transferred to a remaining (secondary) port.

 

 

As soon as the primary port regains functionality, the active

 

 

link is transferred back to the primary port.

 

 

An integer indicating the port number of the physical port

 

 

assigned to the interface. The default is 0 (zero).

 

 

The default value of zero means that the currently active

 

 

link remains in use until it fails. If the port fails, the link is

 

 

transferred to another port. The link remains active on the

 

 

port to which it was transferred, even after the failed port

 

 

regains functionality.

 

 

The primary port setting applies only when you have

 

 

configured more than one port in the interface, and the

 

 

mode is failover.

 

 

 

3Click Apply on the toolbar to send the current changes to the Nortel

SNAS 4050. Click Commit on the toolbar to save the changes permanently.

Nortel Secure Network Access Switch 4050 User Guide

Page 513
Image 513
Nortel Networks 4050 manual Link is transferred back to the primary port