794Chapter 17 Configuration example

Configuring SSH

In this example, the assumption is that the Nortel SNAS 4050 public key has already been uploaded to the TFTP server (10.20.20.20).

5510-48T(config)#ssh download-auth-key address 10.20.20.20 key-name sac_key.1.pub

5510-48T(config)# ssh

Configuring the Nortel SNAS 4050 pVIP subnet

5510-48T(config)#nsna nsnas 10.40.40.0/24

Creating port-based VLANs

5510-48T(config)#vlan create 210 type port

5510-48T(config)#vlan create 220 type port

5510-48T(config)#vlan create 230 type port

5510-48T(config)#vlan create 240 type port

Configuring the VoIP VLANs

5510-48T(config)#nsna vlan 240 color voip

Configuring the Red, Yellow, and Green VLANs

5510-48T(config)#nsna vlan 210 color red filter red

5510-48T(config)#nsna vlan 220 color yellow filter yellow yellow-subnet 10.120.120.0/24

5510-48T(config)#nsna vlan 230 color green filter green

320818-A

Page 794
Image 794
Nortel Networks 4050 manual Configuring SSH, 5510-48Tconfig# ssh, 5510-48Tconfig#nsna nsnas 10.40.40.0/24