Chapter 12 Configuring SNMP 653

Fields used to add and configure a Threshold monitor are listed in Table 139.

Table 139 Threshold monitor fields

Field

Description

 

 

Name

Specifies the name of this monitor.

 

 

Monitor OID

Specifies the OID value being monitored.

 

 

Low Value

Specifies the lowest acceptable value, beyond which an

 

event is triggered.

 

 

Falling Event

Specifies the event triggered when an OID value is less

 

than the specified Low Value.

 

 

High Value

Specifies the highest acceptable value, beyond which an

 

event is triggered.

 

 

Rising Event

Specifies the event triggered when an OID value is greater

 

than the specified High Value.

 

 

Delta Low Value

Specifies the greatest acceptable drop in value, before an

 

event is triggered.

 

 

Delta Falling Event

Specifies the event triggered when an OID value

 

decreases by more than the specified Delta Low Value.

 

 

Delta High Value

Specifies the greatest acceptable increase in value, before

 

an event is triggered.

 

 

Delta Rising Event

Specifies the event triggered when an OID value increases

 

by more than the specified Delta High Value.

 

 

Comment

Specifies a comment for this monitor.

 

 

Frequency

Specifies the sampling interval, in seconds. The default

 

value is 600.

 

 

Additional OIDs in Event

Specifies any additional OIDs for this monitor to trigger.

 

 

Delta Discontinuity OID

Specifies an OID to monitor for discontinuity.

 

 

Delta Discontinuity OID type

Specifies the type of discontinuity to monitor for. The

 

options are:

 

timeTicks

 

timeStamp

 

dateAndTime

 

 

 

For details on adding a Threshold monitor, see “Adding monitor events” on page 648.

Nortel Secure Network Access Switch 4050 User Guide