Chapter 12 Configuring SNMP 627

The Notification Target menu includes the following options:

/cfg/sys/adm/snmp/target <target ID>

followed by:

ip <IPaddr>

Specifies the IP address to which trap messages are

 

sent.

 

IPaddr is the IP address of the SNMP manager.

 

 

port <port>

Specifies the TCP port used by the SNMP manager.

 

The default is port 162.

 

 

version v1v2cv3

Specifies the SNMP version used by the SNMP

 

manager. Valid options are:

 

v1 — SNMP version 1

 

v2c — SNMP version 2c

 

v3 — SNMP version 3

 

The default is v2c.

 

 

del

Removes the current SNMP manager from the Nortel

 

SNAS 4050 configuration.

 

 

Configuring SNMP events using the CLI

The Nortel SNAS 4050 supports three kinds of SNMP monitors, as defined in the

DISMAN-EVENT-MIB:

boolean — checks the value of a monitored object identifier (OID) against a specific value, and triggers an event if the result matches a specified operation.

threshold — compares a monitored OID against a range of values, and triggers events if the comparison determines that the OID value is rising too quickly, falling too quickly, or falls outside certain boundaries

existence — checks the condition of a monitored OID to determine if it is present, absent, or changed, and triggers an event if the result matches the specified condition

To configure monitors and events defined in the DISMAN-EVENT-MIB, use the following command:

/cfg/sys/adm/snmp/event

The event menu displays.

Nortel Secure Network Access Switch 4050 User Guide

Page 627
Image 627
Nortel Networks 4050 manual Configuring Snmp events using the CLI, Notification Target menu includes the following options