Viking TruSearTM manual Basic Specifications, GAS Connection, Burner Adjustment

Page 3

BASIC SPECIFICATIONS

 

Description

VGIB151T

 

 

VGIB242T

 

 

 

 

 

 

Overall Width

15-5/16” (38.9 cm)

 

 

26 1/4” (66.7 cm)

 

 

Overall Depth

 

 

 

 

 

 

To end of landing ledge

 

31-9/16” (80.2 cm)

 

 

To end of knobs

 

32-5/8” (82.9 cm)

 

 

Overall Height

 

10 1/2” (26.3 cm)

 

 

Cutout Width

14” (35.6 cm)

 

 

24 3/4” (62.9 cm)

 

 

Cutout Depth

 

27-1/2” (69.9 cm)

 

 

Cutout Height

 

10-1/4” (26.0 cm)

 

 

Gas

Natural:

standard residential 1/2” (1.3 cm) ID gas service line.

 

 

Requirements

LP/Propane:

equipped with high capacity hose/regulator assembly for

 

 

 

 

connection to standard 5gal, 20 lb. LP/Propane gas cylinder

 

 

 

 

with Type 1, QCC-1 connection or standard residential 1/2”

 

 

 

 

(1.3 cm) ID gas service line.

 

 

Infrared Burner

 

21,500 BTU Nat./20,000 BTU LP

 

 

Rating

 

(6.3 kW Nat./5.9 kW LP)

 

 

Approximate Shipping

55 lbs. (24.8 kg)

 

 

160 lbs. (72.0 kg)

 

 

Weight

 

 

 

 

 

 

 

 

 

 

 

 

GAS CONNECTION

Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the rating plate agrees with that of the supply. Never connect an unregulated gas line to the appliance. An installer supplied gas shut- off valve must be installed in an easily accessible location. All installer supplied parts must conform to local codes, or in the absence of local codes, with the National electrical Code, ANSI/NFPA 70 and the National Fuel Code, ANSI Z223.1. In Canada: Installation must be in accordance with the current CAN/CGA-B149.1, Natural Gas Installation Code or CAN/CGA-B149.2, Propane Installation Code and/or local codes. All pipe sealants must be an approved type and resistant to the actions of LP gas. Never use pipe sealant on flare fittings. All gas connections should be made by a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation must comply with the National Fuel Gas Code ANSI Z223.1.

The gas burner and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa). The unit must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that system at test pressures equal to or less than 1/2 psi (3.5 kPa).

BURNER ADJUSTMENT

There is no burner adjustment for the infrared burner. Once heated, the flames should glow a bright red color.

1/4”

(.64 cm)

Orifice

FLAME HEIGHT

TruSear BURNER

3

Image 3
Contents Viking Use/Installation Guide Safety Tips Please Read and FollowGeneral Information Basic Specifications Burner AdjustmentGAS Connection Natural Fixed Piping Connection LP/PROPANE Fixed Piping Connection LP/PROPANE Tank Requirements LP/PROPANE Tank ConnectionLeak Testing Installation Procedures for BUILT-IN Installation Performance Checklist BUILT-IN Clearance DimensionsTo light TruSear infrared griller Before Lighting Your Truseartm Infrared GrillerTruSear Infrared Cooking Chart Replacement Parts Cleaning and MaintenanceViking Preferred Service Service InformationProfessional Series Page PS0606VR