BUILT-IN CLEARANCE DIMENSIONS
Min. 6”
(15.2 cm)
to combustible
surfaces
15” W.
FRONT VIEW
155/16” (38.9 cm)
Min. 6”
(15.2 cm)
to combustible
surfaces
24” W.
FRONT VIEW
261/4”” (66.7 cm)
SIDE VIEW
11 3/8”
(28.9 cm)
PERFORMANCE CHECKLIST
A qualified installer should carry out the following checks:
•All internal packaging removed.
•Specified clearances maintained to combustible materials.
•Pressure regulator connected and set.
•Manual
•Check air shutter adjustment - sharp blue flame, no yellow tipping.
•Check for gas leaks (odors) at all gas connections.
•Each burner lights satisfactory, individually or with adjacent burners lit.
Any adjustments necessary that are the result of the installer not following instructions will be responsibility of the installer, dealer or the end user of the product.