TROUBLESHOOTING

Problem

Possible Cause

Solution

 

 

 

Burner will not light

LP gas cylinder is empty

Dispose of empty cylinder and replace with a full one.

using a match

 

 

Excess flow valve tripped in Regulator

Turn Control Knob to “OFF” position. Wait five minutes. Relight LP gas grill. If flame remains to be low, turn off gas. Disconnect the Lp gas cylinder from the Regulator. Reconnect the LP gas cylinder to the Regulator. Perform a leak test. Relight grill. This will reset the excess flow valve.

 

 

Obstructions in burner

Clean burner (See Burner Maintenance in Care and

 

 

 

 

Maintenance section of this manual)

 

 

 

 

 

 

 

Flames blow out

High or gusting winds

Turn front of grill away from wind or increase flame height.

 

 

 

Gas in LP cylinder is low

Check LP gas cylinder. Replace if necessary.

 

 

 

 

 

 

 

Flare up

Grease build up

Clean grill

 

 

 

Excessive fat in meat

Trim fat from meat before grilling

 

Persistent grease fire Grease trapped in Bowl and around burner system

Turn Control Knobs “OFF”. Let fire burn out and remove Cooking Surfaces. After the grill cools, clean all parts.

Humming or whistling Outside temperature, humidi-

from the regulator ty, barometric pressure, and the gas level within the tank may cause the rubber diaphragm inside the regula- tor to vibrate, making a hum- ming or whistling sound.

Although this sound may be alarming, this is NOT dangerous as long as it is not accompanied by the smell of gas. Simply adjust the burner settings and usually the sound will subside. If the humming sound persists, a change in atmospheric conditions will eventually stop the vibration. Should you smell gas, do not use the grill and call Customer Service at 1-800-251-7558

Low flame or low heat

Gas in LP cylinder is low

Check LP gas cylinder. Replace if necessary.

If your problem is not resolved from the information provided above, please call Customer Service at

1-800-251-7558.

REPLACEMENT PARTS

If you need replacement parts, refer to the Parts Diagram and the Parts List to find the exact parts you need.

If you have any questions which require help, contact Customer Service and be sure to mention the model number of your grill.

Parts Diagrams

1

9

2

4

3

8

7

5

6

14

Image 14
Contents For Your Safety Meco CorporationImportant Safeguards Page Preparation and Grill SET-UP Page How to perform a leak test See leak test diagrams next Before Using Your LP GAS GrillLeak Testing Attaching the LP GAS Cylinder to the RegulatorLP Cylinder Operating Your LP GAS GrillGAS CYLINDER, Regulator Information Connecting/ Disconnecting LP Gas Cylinder to Grill Regulator AssemblyPage Turning Off Your LP Gas Grill Grill CookingEnd of Cooking Session Yellow TipHow to Clean the Burners Care and MaintenanceBurner Maintenance Preventive Maintenance Cleaning the GrillPrecautions Grease CupGrill Moving and Storage TroubleshootingBurner will not light using the ignitor Flare up Replacement PartsFlames blow out Low flame or low heatParts List Description QTY REL /2004