Char-Broil 463250308 manual LP Cylinder Exchange, LP Cylinder Leak Test, For your safety

Page 5

LP Cylinder Exchange

•Many retailers that sell grills offer you the option of replacing your empty LP cylinder through an exchange service. Use only those reputable exchange companies that inspect, precision fill, test and certify their cylinders. Exchange your cylinder only for an OPD safety feature-equipped cylinder as described in the "LP Cylinder" section of this manual.

Always keep new and exchanged LP cylinders in upright position during use, transit or storage.

Leak test new and exchanged LP cylinders BEFORE connecting to grill.

LP Cylinder Leak Test

For your safety

Leak test must be repeated each time LP cylinder is exchanged or refilled.

Do not smoke during leak test.

Do not use an open flame to check for gas leaks.

Grill must be leak tested outdoors in a well-ventilated area, away from ignition sources such as gas fired or electrical appliances. During leak test, keep grill away from open flames or sparks.

•Use a clean paintbrush and a 50/50 mild soap and water solution. Brush soapy solution onto areas indicated by arrows in figure below.

?Do not use household cleaning agents. Damage to gas

train components can result.

WARNING

If “growing” bubbles appear do not use or move the LP

cylinder. Contact an LP gas supplier or your fire

department!

Connecting Regulator to the LP Cylinder

1.LP cylinder must be properly secured onto grill. (Refer to assembly section.)

2.Turn all control knobs to the OFF position.

3.Turn LP cylinder OFF by turning hand-wheel clockwise to a full stop.

4.Remove the protective cap from LP cylinder valve. Always use cap and strap supplied with valve.

lo

ck

 

wi

ff C

 

se

O

 

 

OPD Hand Wheel

Type 1 outlet with thread on outside

Safety Relief Valve

Strap and Cap

Do not use a POL transport plug (plastic part with external threads)! It will defeat the safety feature of the valve.

5.Hold regulator and insert nipple into LP cylinder valve. Hand-tighten the coupling nut, holding regulator in a straight line with LP cylinder valve so as not to cross-thread the connection.

Nipple has to be centered into the LP cylinder valve.

463250308 • 5

Image 5
Contents Model 463250308 Product Guide Installation Safety Precautions Call Grill Service Center for Help and PartsSafety Symbols For residential use only. Do not use for commercialTable of Contents LP Cylinder Filling LP Liquefied Petroleum GasUL listed Overfill Protection Only LP cylinders equipped with this type of valveFor your safety Connecting Regulator to the LP Cylinder?Do not use household cleaning agents. Damage to gas LP Cylinder ExchangeConnection, do not use this regulator Leak Testing Valves, Hose and RegulatorTurn all grill control knobs to OFF ?Never remove threaded orifice at end of valveMain Burner Ignitor Lighting For Safe Use of Your Grill and to Avoid Serious InjurySide burner Ignitor Lighting General Grill CleaningSide burner Match Lighting Burner Flame CheckStoring Your Grill Cleaning the Burner AssemblyTurn gas off at control knobs and LP cylinder BurnerFood Safety 463250308 Stubborn Stains and Rust Routine CareEstimated assembly time 30-45 minutes Tools required for assemblyKey DescriptionParts Diagram Model No Right side of the drawer Right Shelf Handle and Drawer handle AssemblyLeft side of the drawer Attach side burner shelf onto left side panel using one 1/4 Right and Left Shelf AssemblyTank Gauge Assembly Gauge WireValve Side Burner AssemblyBurner Tube Side burner Control Knob Assembly Locked Position E R Trough InstallCooking Grate and Swing away Sure tank valve is facing front of grill Important safety instructions before usingLP Tank Electronic Ignition Battery CapEmergencies Possible Cause Prevention/Solution TroubleshootingElectronic Ignition Section Troubleshooting Electronic IgnitionLimited warranty Limited WarrantyPlease register your product online at This Intentionally Blank This Intentionally Blank Thank You for Your Purchase Grilling Safety Checklist