Char-Broil 473721007 manual Never fill a cylinder beyond 80% full, LP Liquefied Petroleum Gas

Page 4

USE AND CARE

DANGER

NEVER store a spare LP cylinder under or near the appliance or in an enclosed area.

Never fill a cylinder beyond 80% full.

An over filled or improperly stored cylinder is a hazard due to possible gas release from the safety relief valve.

If you see, smell or hear gas escaping, immediately get away from the LP cylinder/appliance and call your fire department.

If the above is not followed exactly, a fire causing death or serious injury may occur.

LP Cylinder Removal, Transport and Storage

Turn OFF all control knobs and LP cylinder valve. Turn coupling nut counterclockwise by hand only - do not use tools to disconnect .Loosen cylinder screw beneath bottom shelf, then lift LP cylinder up and out of cart. Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve. Always use cap and strap supplied with valve. Other types of caps or plugs may result in leakage of propane. Failure to use dust cap as directed may result in serious personal injury and/or property damage.

• A disconnected LP cylinder in

LP Cylinder Valve

 

storage or being transported

 

 

must have a dust cap installed (as shown).

 

Do not store an LP cylinder in enclosed spaces

 

such as a carport, garage, porch, covered

Dust

patio or other building. Never leave an LP cylinder

inside a vehicle which may become overheated

Cap

 

by the sun.

Retainer Strap

• Do not store an LP cylinder in an area where children play.

LP Cylinder

The LP cylinder used with your grill must meet the following requirements:

Use LP cylinders only with these required measurements: 12" (30.5cm) (diameter) x 18" (45.7 cm) (tall) with 20 lb. (9 kg.) capacity maximum.

LP cylinders must be constructed and marked in accordance with specifications for LP cylinders of the U.S. Department of Transportation (DOT). See LP cylinder collar for marking.

LP cylinder valve must have:

• Type 1 outlet compatible with

 

regulator or grill.

 

Safety relief valve.

 

UL listed Overfill Protection

OPD Hand Wheel

 

Device (OPD). This OPD safety

 

 

feature is identified by a unique triangular hand wheel. Use

only LP cylinders equipped with this type of valve.

LP cylinder must be arranged for vapor withdrawal and include collar to protect LP cylinder valve. Always keep LP cylinders in upright position during use, transit or storage.

LP cylinder in upright position for vapor withdrawal

LP (Liquefied Petroleum Gas)

LP gas is nontoxic, odorless and colorless when produced. For Your Safety, LP gas has been given an odor (similar to rotten cabbage) so that it can be smelled.

LP gas is highly flammable and may ignite unexpectedly when mixed with air.

LP Cylinder Filling

Use only licensed and experienced dealers.

LP dealer must purge new cylinder before filling.

Dealer should NEVER fill LP cylinder more than 80% of LP cylinder volume. Volume of propane in cylinder will vary by temperature.

A frosty regulator indicates gas overfill. Immediately close LP cylinder valve and call local LP gas dealer for assistance.

Do not release liquid propane (LP) gas into the atmosphere. This is a hazardous practice.

To remove gas from LP cylinder, contact an LP dealer or call a local fire department for assistance. Check the telephone directory under “Gas Companies” for nearest certified LP dealers.

4 • 473721007

Image 4
Contents Leave this manual with consumer Protective gloves if necessaryKeep this manual for future reference Some parts may contain sharp edgesSafety Symbols See rating label on grill for serial numberOnline at Never fill a cylinder beyond 80% full LP Cylinder Removal, Transport and StorageLP Liquefied Petroleum Gas LP Cylinder FillingConnecting Regulator to the LP Cylinder LP Cylinder ExchangeLP Cylinder Leak Test OPD Hand WheelLeak Testing Valves, Hose and Regulator Turn all grill control knobs to OFFSafety Tips If you have a grill problem see the Troubleshooting SectionFor Safe Use of Your Grill and to Avoid Serious Injury Apartment DwellersGeneral Grill Cleaning Ignitor LightingMatch-Lighting Burner Flame CheckCleaning the Burner Assembly Storing Your GrillTurn gas off at control knobs and LP cylinder Portion of electrode with rubbing alcohol and a swabFood Safety How To Tell If Meat Is Grilled Thoroughly80009004 8001267080012671 80008000Parts Diagram Model No Leg assembly, Right Leg Assembly, Left All until Step80012672 80012673 80012682Large Flat Washer#10-24 X Machine Screw Qty When the control panel is ALLIgnitor 80008322Valve/Hose/Regulator 80009002 Fiber Washer Qty Firebox Valve Heat#10-24 Flange Nut Qty 4Fiber Washer Ignitor Wire#8-32x1/4 Machine Screw Qty #10-24 Flange Nuts #10-24X1/2 Qty#10-24X1/2’ Qty2 Fiber Washer Wing Nut Upper Hinge KitVaporiser Bar Knob Leg Wire Swing Away Grid AssemblyGrease Cup Clip Attach tool hooks to the right side shelf Correctly Installed LP cylinder RegulatorTroubleshooting Using ignitor Push-button sticks at bottom Replace ignitor Cleaning section of Use and CareReplace knob Insulation is brokenLimited Warranty Please register your grill online at Envíelo aGrilling Safety Checklist Thank You for Your Purchase