Milwaukee LMDVT-3328CNM Maintenance Schedule, Maintenance Task Accomplishing Person Procedure

Page 22

22

MAINTENANCE SCHEDULE

Annually (Before the onset of the Burning Season)

MAINTENANCE TASK

 

ACCOMPLISHING PERSON

PROCEDURE

 

 

 

 

Inspecting/Cleaning Burner, Logs

 

Qualified Service Technician

Inspect valve and ensure it is properly operating. Check piping

and Controls

 

 

for leaks. Vacuum the control compartment, fireplace logs and

 

 

 

burner area.

 

 

 

 

Check Flame Patterns and Flame

 

Qualified Service Technician

Refer to Figure 10 (LMDV-3328 & LMDV-3530) or Figure 11

Height

 

 

(LMDV-4035)on Page 10 and verify the flame pattern and height

 

 

 

displayed by the appliance conforms to the picture. Flames

 

 

 

must not impinge on the logs. Ensure flames are steady (not

 

 

 

lifting or floating).

 

 

 

 

Inspecting/Cleaning Pilot and Burner

 

Qualified Service Technician

Refer to Figure 13 (SIT Millivolt), Figure 14 (Honeywell Millivolt)

 

 

 

or Figure 15 (Electronic) on Page 11. Remove any surface

 

 

 

build-up on pilot and burner assembly. Wipe the pilot nozzles,

 

 

 

igniter/flame rod and hood. Ensure the pilot flame engulfs the

 

 

 

flame sensor as shown.

 

 

 

 

Checking Vent System

 

Qualified Service Technician

Inspect the vent system at the top and at the base (within the

 

 

 

firebox) for signs of blockage or obstruction. Look for any signs

 

 

 

of dislocation or deterioration of the vent components. Note:

 

 

 

Excessive condensation can cause corrosion of caps, pipe &

 

 

 

fittings (excessive condensation can be caused by long lateral

 

 

 

runs, too many elbows and/or exterior portions of the system

 

 

 

being exposed to cold weather). Also inspect wall straps or

 

 

 

plumbers's tape to ensure it is secure and in place.

 

 

 

 

Appliance Checkout

 

Qualified Service Technician

Perform the appropriate appliance checkout procedure detailed

 

 

 

in this manual.

 

 

 

 

Replacing Rockwool Ember Materials

 

Homeowner/Qualified Service

Remove old ember materials (rockwool) and vacuum the ember

 

 

Technician

placement area. Place new embers as described and shown in

 

 

 

Figures 8 & 9.

 

 

 

 

Periodically (After the Burning Season)

 

 

 

 

 

MAINTENANCE TASK

 

ACCOMPLISHING PERSON

PROCEDURE

 

 

 

 

Cleaning Firebox Interior

 

Homeowner

Carefully remove logs, rockwool, volcanic stone and vermiculite.

 

 

 

Vacuum out interior of the firebox. Clean firebox walls and log

 

 

 

grate. Replace logs, rockwool, vermiculite and volcanic stone

 

 

 

as detailed in this manual.

 

 

 

 

Check Flame Patterns and Flame

 

Homeowner

Refer to Figure 10 (LMDV-3328 & LMDV-3530) or 11 (LMDV-

Height

 

 

4035) on Page 10 and verify the flame pattern and height dis-

 

 

 

played by the appliance conforms to the picture. Flames must

 

 

 

not impinge on the logs.

 

 

 

 

Checking Vent System

 

Homeowner

Inspect the vent system at the top and at the base (within the

 

 

 

firebox) for signs of blockage or obstruction. Look for any signs

 

 

 

of dislocation of the vent components.

 

 

 

 

Cleaning Front Glass Enclosure Panel

 

Homeowner

Clean as necessary following the directions provided in this

 

 

 

manual. Do not touch or attempt to clean glass

 

 

 

while hot.

 

 

 

 

Image 22
Contents Carefully supervise children in the same room as appliance OTL Report No -F-31-5Table of Contents Burn-in Period Gas Controls/Control Compartment AccessGas Pressure Operation and care of your applianceElectronic Appliances ON/OFF SwitchVariable Flame Height Adjustment Millivolt Appliances only Port InletMaintenance See Maintenance Schedule,Removing Glass Enclosure Panels Front Glass Enclosure Panel, Removal and InstallationInstalling Glass Enclosure Panels Glas s Door LatchFirebox Accessories/Parts Placement of Logs and TwigsLMDV-3328 & LMDV-3530 Install as Follows Model LMDV-3328 & LMDV-3530 Log Placement Instructions Catalog Number H3366Model LMDV-4035 Catalog Number H3365Burner Air Shutter Adjustment Procedure Burner AdjustmentsAir Shutter Adjustment Guidelines Flame Appearance and sootingReplacement parts Burner Air Shutter AdjustmentWarranty Product reference informationThermopile Optional Switch Wiring DiagramsMillivolt Wiring Diagram Schematic Representation Only Standard OFF/ON SwitchAccessory Components Product Reference Information Barrier Screen Panel Kit Accessory ComponentsDecorative Arch Screen Panel Kit Forced Air Kit Variable Speed Wall SwitchOFF/ON Wall Switch Kit Bag of Glowing Embers Bag of Volcanic StonePolished Brass & Brushed Stainless Louvers Kits Touch-Up Paint KitTermination Guard Kits Polished Brass & Brushed Stainless 2-Piece Door Frame KitsDecorative Grille Kits Tall Style View DoorsTo Pilot Lighting InstructionsTo Turn OFF GAS to Appliance Push in control knob all the way and holdInstructions Dallumage Pour Fermer LE GAZ QUI Alimente L’APPAREILTo shut off Honeywell Electronic Gas Control Valve ON/OFF SwitchWhat to do if YOU Smell GAS Front ViewFermez la porte du compartiment de contrôle du bas Manual. Do not touch or attempt to clean glass Maintenance ScheduleMaintenance Task Accomplishing Person Procedure While hotTroubleshooting Symptom Possible Causes Corrective ActionWhen measuring voltage Troubleshooting Procedure Electronic Ignition SystemIgniter will cycle off Page Gas Controls Honeywell Millivolt Replacement Parts ListGas Controls SIT Millivolt Gas Controls Honeywell ElectronicReplacement Parts 28 P/N 875,028M REV. E 02/2008