22
MAINTENANCE SCHEDULE
Annually (Before the onset of the Burning Season)
MAINTENANCE TASK |
| ACCOMPLISHING PERSON | PROCEDURE |
|
|
|
|
Inspecting/Cleaning Burner, Logs |
| Qualified Service Technician | Inspect valve and ensure it is properly operating. Check piping |
and Controls |
|
| for leaks. Vacuum the control compartment, fireplace logs and |
|
|
| burner area. |
|
|
|
|
Check Flame Patterns and Flame |
| Qualified Service Technician | Refer to Figure 10 |
Height |
|
| |
|
|
| displayed by the appliance conforms to the picture. Flames |
|
|
| must not impinge on the logs. Ensure flames are steady (not |
|
|
| lifting or floating). |
|
|
|
|
Inspecting/Cleaning Pilot and Burner |
| Qualified Service Technician | Refer to Figure 13 (SIT Millivolt), Figure 14 (Honeywell Millivolt) |
|
|
| or Figure 15 (Electronic) on Page 11. Remove any surface |
|
|
| |
|
|
| igniter/flame rod and hood. Ensure the pilot flame engulfs the |
|
|
| flame sensor as shown. |
|
|
|
|
Checking Vent System |
| Qualified Service Technician | Inspect the vent system at the top and at the base (within the |
|
|
| firebox) for signs of blockage or obstruction. Look for any signs |
|
|
| of dislocation or deterioration of the vent components. Note: |
|
|
| Excessive condensation can cause corrosion of caps, pipe & |
|
|
| fittings (excessive condensation can be caused by long lateral |
|
|
| runs, too many elbows and/or exterior portions of the system |
|
|
| being exposed to cold weather). Also inspect wall straps or |
|
|
| plumbers's tape to ensure it is secure and in place. |
|
|
|
|
Appliance Checkout |
| Qualified Service Technician | Perform the appropriate appliance checkout procedure detailed |
|
|
| in this manual. |
|
|
|
|
Replacing Rockwool Ember Materials |
| Homeowner/Qualified Service | Remove old ember materials (rockwool) and vacuum the ember |
|
| Technician | placement area. Place new embers as described and shown in |
|
|
| Figures 8 & 9. |
|
|
|
|
Periodically (After the Burning Season) |
|
| |
|
|
| |
MAINTENANCE TASK |
| ACCOMPLISHING PERSON | PROCEDURE |
|
|
|
|
Cleaning Firebox Interior |
| Homeowner | Carefully remove logs, rockwool, volcanic stone and vermiculite. |
|
|
| Vacuum out interior of the firebox. Clean firebox walls and log |
|
|
| grate. Replace logs, rockwool, vermiculite and volcanic stone |
|
|
| as detailed in this manual. |
|
|
|
|
Check Flame Patterns and Flame |
| Homeowner | Refer to Figure 10 |
Height |
|
| 4035) on Page 10 and verify the flame pattern and height dis- |
|
|
| played by the appliance conforms to the picture. Flames must |
|
|
| not impinge on the logs. |
|
|
|
|
Checking Vent System |
| Homeowner | Inspect the vent system at the top and at the base (within the |
|
|
| firebox) for signs of blockage or obstruction. Look for any signs |
|
|
| of dislocation of the vent components. |
|
|
|
|
Cleaning Front Glass Enclosure Panel |
| Homeowner | Clean as necessary following the directions provided in this |
|
|
| manual. Do not touch or attempt to clean glass |
|
|
| while hot. |
|
|
|
|