TROUBLESHOOTING
Note: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, iff applicable), is in the “ON” position.
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
TROUBLESHOOTING GUIDE - Millivolt GAS CONTROL SYSTEM
| SYMPTOM | POSSIBLE CAUSES | CORRECTIVE ACTION |
1. | Spark igniter will not light pilot after | A. Defective igniter | Check for spark at electrode and pilot; if no spark and |
| repeated triggering of igniter button. | (no spark at electrode). | electrode wire is properly connected, replace igniter. |
| WARNING: if the pilot will not light | B. Defective or misaligned electrode at pilot | Using a match, light pilot. If pilot lights, turn off pilot |
| (spark at electrode). | and trigger the igniter button again. If pilot lights, an | |
| after 1 minute of attempting, wait | ||
|
| improper gas mixture caused the bad lighting and a | |
| for at least 5 minutes for gas to |
| |
|
| longer purge period is recommended. If pilot will not | |
| clear before attempting again. |
| |
|
| light – check gap at electrode and pilot – should be 1/8" | |
|
|
| |
|
|
| to have a strong spark. If gap measures 1/8", replace |
|
|
| pilot (see Figures 13 or 14 on Page 11). |
|
| C. Gas supply pressure errant. | Check inlet gas pressure. It should be within the limits |
|
|
| as marked on the rating plate. |
|
| D. Pilot orifice plugged. | Clean or replace pilot orifice. |
|
|
|
|
2. | Pilot will not stay lit after | A. Defective pilot generator | Check pilot flame, it must impinge on thermocouple |
| carefully following the lighting | (thermocouple). | (see Figures 13 or 14 on Page 11). Clean and/or |
| instructions. |
| adjust pilot for maximum flame impingement on |
|
|
| thermocouple. Ensure that the connection between |
|
|
| the valve and thermocouple are tight and secure. |
3. | Pilot burning, no gas to burner, Valve | A. Wall switch or wires defective. | Check wall switch and wires for proper connections. |
| knob “ON,” and the (standard) burner |
| Jumper wire across terminals at wall switch, if burner |
| OFF/ON switch is “ON." Read impor- |
| comes on, replace defective wall switch. If okay, jumper |
| tant note below. |
| wires across wall switch wires at valve, if burner comes |
|
|
| on, wires are faulty or connections are bad. |
| IMPORTANT NOTE: If an optional | B. Thermopile may not be generating suf- | Check thermopile with millivolt meter. Take reading |
| ficient millivolts. | at thermopile terminals of gas valve. Should read | |
| *remote switch is used for burner | ||
|
| 325 millivolts minimum with optional wall switch | |
| operation, if the standard burner |
| |
|
| “OFF.” Replace faulty thermopile if reading is below | |
| OFF/ON switch is still installed on |
| |
|
| specified minimum. | |
| appliance it must be in the "OFF" |
| |
| position. | C. Plugged burner orifice. | Check burner orifice for blockage and remove. |
|
| ||
| *Optional remote switch kits - wall |
|
|
| D. OFF/ON Switch & *Remote Switch are in | When turning on the burner using a *remote switch, | |
| switch, wall thermostat or remote | the "ON" position resulting in excessive | ensure that the standard OFF/ON switch is in the "OFF" |
| control. | resistance. | position. If both switches are in the ON position, it |
|
|
| may result in excessive resistance (& millivolt drain- |
|
|
| age) and the burner may not come on. |
4. | Frequent pilot/burner outage prob- | A. Pilot flame may be too low or blowing (high) | Clean and/or adjust pilot flame for maximum flame |
| lem. | causing the pilot/valve safety to drop out. | impingement on thermocouple (see Figures 13 or |
|
|
| 14 on Page 12). |
| TROUBLESHOOTING GUIDE - ELECTRONIC IGNITION SYSTEM | |||
|
|
|
|
|
| SYMPTOM | POSSIBLE CAUSES | CORRECTIVE ACTION |
|
|
|
|
|
|
1. | Burner will not light. | A. Faulty Valve System. | See Below. |
|
|
|
|
|
|
|
| B. “OFF/ON” or wall switch defective. | Disconnect the two black wires from the wire nuts. |
|
|
|
| Test switch(s) for continuity with a multimeter. If |
|
|
|
| continuity is not indicated, switch(s) is defective and |
|
|
|
| must be replaced. |
|
|
|
| Note: Before replacing “OFF/ON” switch, Ensure to |
|
|
|
| check wiring for loose connections or broken wires |
|
|
|
| and repair as needed. |
|
2. | Burners come “ON,” then turns “OFF.” | A. Burner orifice plugged. | Check main burner orifice(s) for blockage. Clean |
|
|
|
| or replace. |
|
|
| B. Obstructed vent system. | Check vent system for obstructions. |
|
|
|
|
|
|
|
| NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. | 23 |