Procom AL500HYLA installation manual Installation Instructions

Page 4

INSTALLATION INSTRUCTIONS

Continued

5.Install logs 1,2,3,4,5 by inserting each log screw into holes of corresponding grate branch . Make sure each log is placed in proper sequence.(See FIG 5.)

Note: If the log is too loose or the screw can’t be pulled down after inserting the log screw, screw the nuts to adjust the clearance between nuts and logs.

Figure 5-Installing log 1.2.3.4.5

6. Install logs 6,7,8,9,10 as step 5.(See FIG.6)

Figure 6-Installing log 6.7.8.9.10

7.Attach the four columns to the burner plate with M4×10 screws provided. Do not tighten at this time. (See FIG.7)

Figure 7-Column installation

4

AL058-01

Image 4
Contents Outdoor GAS Fireplace Product Identification Local Codes Safety InformationUnpacking Product Features InstallationInstallation Instructions Connecting to GAS Supply InstallationMaintenance and Storage Operating HeaterCleaning and Maintenance General InformationReplacement Parts Parts Under Warranty ReplacementParts not Under Warranty Parts List HP500MA KEY Part Description QTY NumberIllustrated Parts Breakdown AL500HYLAParts List HP500MA AL058-01 Logs List AL500HYLA PRO-COM Toll-Free number