Majestic Appliances ODSHR42 manual Hearth Installation, Example for Common Brick

Page 15

ODSHR Series

Minimum Wall Clearances

WITH

WITHOUT

Noncombustible

Noncombustible

Surround Facing

Surround Facing

 

Shaded area starts

4" Brick

3/4" away from

edge of unit

(Example material)

 

 

 

4"

18" 14"**

Firebox

18"

 

Opening

39¹⁄₂"

32¹⁄₂"**

22" - Min. clearance

 

 

to combustible

 

 

perpendicular wall

 

Side

18" - Min. clearance

Side

Wall

to combustible

Wall

 

perpendicular wall when

 

 

using noncombustible wall shield*

 

Combustible material permitted within shaded area.

*Noncombustible wall shield requires 1" Majestic EH2416 insulation (minimum R Value = 1.85) between decorative noncombustible rigid covering and combustible wall.

Minimum height and width is 40" x 40".

**Dimension/degree of angle will vary depending on thickness of noncombustible surround facing.

Minimum Hearth Extension Dimensions

(for On-Site Construction)

 

12"

12"

 

20"

 

 

 

66"

 

Seal cracks

 

May install

between the

 

noncombustible

fireplace

 

decorative

and hearth

 

covering

extension with

 

OR .018" min.

noncombustible

 

sheet metal

material

Fireplace

 

 

 

 

Hearth

4" Min.

 

 

Combustible

Minimum

Safety strips

Floor

Insulation

must overlap

 

Value "R":

¹⁄₂" minimum

FP532b

Fig. 24 Combustible side wall protection and hearth extension dimensions.

8. Hearth Installation

A hearth extension is required to protect a combustible floor in front of the fireplace. See Figure 24 for mini- mum dimensions and mounting detail.

NOTE: Hearth Extension must not cover the air inlet opening of a fireplace.

The hearth extension described in Figure 24 must be a durable noncombustible material with a minimum (total) Rt value of 1.09; see Figure 25 for examples. The overall height (above a combustible floor), depth and width must be as indicated, with the extension centered to the fireplace opening.

The top of insulation must be covered with a non- combustible decorative covering or a piece of .018” minimum sheet metal, to protect hearth extension material. (Fig. 24)

Secure the hearth extension to the floor to prevent shifting, using trim molding or other similar means at three (3) outer edges. Seal crack between the fireplace hearth and hearth extension with a noncombustible material. (Figs. 24, and 26 - 28)

WARNING: HEARTH EXTENSION MUST BE IN- STALLED IN ACCORDANCE WITH FIGURE 24.

Alternate noncombustible materials may be used providing the (total) thermal resistance (Rt value) of the alternate material employed is greater than or equal to R = 1.09. Thermal resistance (R) or thermal conductiv- ity (K), may be obtained from manufacturer of the material. Factors are related by the formula K = 1/R. (Fig. 25)

T = given thickness

R = thermal resistance for a given thickness (T) K = thermal conductivity

Non-combustible material with a lower R value may be used, provided thickness of material is sufficiently greater to maintain an equivalent (total) thermal resis- tance (Rt).

Example of Determining Hearth Extension Equivalents

To determine the thickness required for any new material:

NEW

 

K of new material (per inch)

thickness

required

+

 

 

X of listed

 

 

thickness

 

K of listed material (per inch)

material

Example for Common Brick

T (new) = 5.0/0.458 x 0.50 in. = 5.46 in. (new required thickness).

20002264

15

Image 15
Contents Odshr Series Table Of Contents Safety InformationODSHR42 Series Woodburning Fireplace Chase Installation Chimney Requirements Offset Installations Ten Foot Rule Planning InformationMounting the Fireplace Planning the Chimney RunInsulating Fireplace Enclosure for Cold Climates InstallationChase Installation Chimney SupportsChimney Set-Up Straight-Up Chimney InstallationOffset Installation FramingFraming the Ceiling Hole Cutting the HoleInstalling Outside Air Kit Positioning, Safety Strips, Securing the FireplaceInstalling the Chimney System Installing the Firestop Spacer Ceiling HoleProper Firestop Spacer Installation Installing Chimney In a Chase Continue Installing Pipe to Complete RunInstall Remainder of Chimney Sections Installing Top Housing or TerminationFront View Side View Finish WallExamples of wall shield insulation Side Wall ProtectionHearth Installation Example of Determining Hearth Extension EquivalentsExample for Common Brick Common Materials and Factors Installing Line for Gas LogsGas line access 9a,b Description Part NumberAccessory Description Model No AccessoriesFirebox Record RLTCF11LLimited Warranty & 30 Year Protection Plan Vermont Castings, Majestic Products