Napoleon Grills UP405 manual GAS HOOK-UP Instructions, Leak Testing Instructions

Page 5

GAS HOOK-UP INSTRUCTIONS

CYLINDER CONNECTION: Ensure that the gas regulator hose is kink free. Remove the cap or plug from the cylinder fuel valve. Insert the black QCC1 regulator nipple onto the QCC1 fuel valve. Hand tighten clockwise. Do not use tools. Leak test all joints prior to using the barbecue. A leak test must be performed annually, and each time a cylinder is hooked up, or if a part of the gas system is replaced.

PROPANE CYLINDER INSTALLATION: Set cylinder into the groove of the lower tank mounting bracket. Ensure that tank valve faces away from the barbecue. Lower the top tank mounting bracket onto the cylinder and tighten with wing nut.

IMPORTANT: Ensure that the hose is routed around the front side of the cart leg to maintain proper clearance to the underside of the unit.

NATURAL GAS HOOK-UP:This natural gas grill is supplied with a 10ft supply hose (complete with a quick disconnect) designed for natural gas and certified for outdoor use. The gas grill is designed to operate at an inlet pressure of 7 inches water column. A regulator must be installed if the house pressure is greater than 7 inches water column. Piping and valves upstream of the quick disconnect are not supplied.

The quick disconnect must not be installed in an upward direction and a readily accessible manual shut-off valve must be installed upstream of, and as close to, the quick disconnect as is feasible. The flared end of the hose must be connected to the unit as illustrated in the Natural Gas Hose Attachment diagram. These connections must be made by a licensed gas installer. Leak test all joints prior to using the gas grill.

IMPORTANT: Ensure that the hose is routed around the front side of the cart leg to maintain proper clearance to the underside of the unit.

NON-SIDE BURNER UNITS: Connect the flared end of the hose to the fitting on the end of the manifold tube. Wrench tighten. (Do not use thread sealer/pipe dope.)

SIDE BURNER UNITS: Connect the 20" hose from the manifold, to the side burner as illustrated in the Natural Gas Hose Attachment diagram. Connect the supply hose to the flare connection which faces down from the side burner. Tighten all connections using two wrenches. (Do not use thread sealer/pipe dope.)

LEAK TESTING INSTRUCTIONS

Do not use a flame to leak test.

LEAK TESTING: This must be done before initial use, annually and whenever any gas components are replaced or serviced. No smoking while performing this test, and remove all sources of ignition. See Leak Testing Diagram for areas to check.

1.Turn all burners controls to off. Turn supply valve on.

2.Brush a half and half solution of liquid soap and water onto all joints and connections of the regulator, hose, manifolds and valves.

3.Bubbles will indicate a gas leak. Either tighten the loose joint or replace the part with one recommended by the dealer.

4.If the leak cannot be stopped, shut off the gas supply, disconnect it and have the barbecue inspected by your gas supplier or dealer. Do not use the appliance until the leak has been corrected.

5.Turn off gas supply.

5

Image 5
Contents UP405 Pedestal U405 Cart Safe Operating Practices Napoleon GAS Grill Ultrachef Limited Lifetime Warranty Important DOS and Donts General InformationGAS HOOK-UP Instructions Leak Testing InstructionsLighting Instructions Cooking Instructions Cleaning InstructionsYellow Tipping Approximately Dark Blue Maintenance InstructionsProblem Possible Causes Solution TroubleshootingOrdering Replacement Parts / Returns Avertissement Conditions ET Limitations Quoi Faire ET NE PAS Faire Information GénéraleInstructions DE Branchement DU GAZ Test DE Détection DE FuitesOuvrir le couvercle Instructions D’ALLUMAGENettoyage Instructions D’OPÉRATIONInstructions D’ENTRETIEN Guide DE Dépannage Problème Causes Probables SolutionCommande DES Pièces DE Rechange / Retours N570-0027 #14 X N570-0026 #14 x 1/2 Pedestal Model only N570-0026 #14 x 1/2 N570-0026 #14 x 1/2 Optional Locking Screw VIS DE Verrouillage Optionnelle N570-0026 #14 x 1/2 N450-0005 N305-0041 N305-0044 N520-0012K N160-0002 Leak Testing Test DE Détection DE Fuites UP405RB Parts List / Liste DE PiècesFAX to