CFM Corporation SHR48, SHR52, SHR42A, SHR36 manual SLTCF11

Page 22

SHR Series Woodburning Fireplace

Accessory

Description

Model No.

 

 

 

Contemporary Flashing

Required for contemporary top termination

8-6-12

 

on the roof to prevent rain entry.

(0 to 6/12 pitch)

 

 

8-12-12

 

 

(6/12 to 12/12 pitch)

 

 

 

Contemporary Chase Top Termina-

Used to terminate chimney at the top of a

SLTCF11

tion

chase. Adapter kit is included, flashing is

 

 

not included.

 

 

 

 

Contemporary Round Top Termina-

For use with CFM Corporation Type

RLTCF11

tion

"11CF" Chimney Systems.

 

 

Used to terminate chimney on the roof.

 

 

Flashing not included.

 

 

 

 

Extended Round Top

For use with CFM Corporation Type

RLTCF11L

 

"11CF" Chimney Systems.

 

 

Used to terminate chimney at top of

 

 

chase. Adapter kit included. Flashing not

 

 

included.

 

 

 

 

Chimney Sections

Used to build "11CF" chimney systems.

11" flue

 

 

11CF1 (1' long)

 

 

11CF18 (1¹⁄₂' long)

 

 

11CF3 (3' long)

 

 

11CF4 (4' long)

 

 

 

 

Used to develop 30° offset chimney sys-

11CF30-2

Chimney Elbows

tems. (Elbows packed 2 per carton - upper

(11" 30° flue)

 

and lower elbow set)

 

 

 

 

 

Gives traditional chimney top look using

S20BR/BT/BW

Top Housing with

simulated brick in red, tan or white color.

S20UB (Upper Baffle)

Upper Baffle

Brick pattern is embossed into galvanized

 

 

steel unit. Roof flashing is included. Appro-

 

 

priate adapter is required. Must be used

 

 

with upper baffle.

 

 

 

 

Attic Insulation Shield

Used to prevent insulation from coming sin

FS2100-HT

 

contact with the chimney system. For use

 

 

with CF11 pipe.

 

 

 

 

22

20001384

Image 22
Contents SHR Series Safety Information Table of ContentsSHR36 Series Woodburning Fireplace SHR48 Series Woodburning Fireplace Chase Installation 30˚ Elbow Offsets Chimney Requirements Offset InstallationsIllustration Key Planning the Chimney Run Planning InformationMounting the Fireplace Ten Foot RuleChimney Supports InstallationChase Installation Insulating Fireplace Enclosure for Cold ClimatesFraming Firebrick InstallationChimney Set-up Ceiling Chimney Hole Possible Obstructions Straight-Up Chimney InstallationOffset Installation Cutting the HolePositioning, Safety Strips Securing the Fireplace Installing Outside Air KitInstalling the Firestop Spacer Ceiling Hole Installing the Chimney SystemProper Firestop Spacer Installation Additional Ceilings Continue Installing Pipe to Complete RunCanadian Requirements For Insulation Shield Penetrating the RoofInstalling Chimney in a Chase Install Remainder of Chimney SectionsInstalling Top Housing or Termination Cut and Frame Roof HoleMantel clearance Facing on fireplace surround flush with finished wall Example of Determining Hearth Extension Equivalents Hearth InstallationSide Wall Protection Example for Common BrickMinimum Hearth Extension Dimensions Minimum Wall ClearancesInstalling Line for Gas Logs Sealing detailSHR36/42A/48/52 Woodburning Fireplace Accessories Accessory Description Model NoSLTCF11 Limited Warranty & 30 Year Protection Plan For Majestic Fireplaces PRE-ENGINEERED Fireplace SystemsCFM Corporation