Heat & Glo LifeStyle OGL-42 Troubleshooting S Series, Symptoms Possible Causes Corrective Action

Page 11

 

 

 

 

 

OGL-42 INSTALLATION INSTRUCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F. TROUBLESHOOTING - “S” SERIES

 

 

 

 

 

 

Symptoms

Possible Causes

Corrective Action

 

 

 

 

 

 

 

 

 

1.

Match will not light pilot.

a.

Main gas shutoff valve

Make sure that the shutoff valve located on the incoming

 

 

 

 

 

closed.

gas line is open.

 

 

 

 

 

 

 

 

 

 

 

b.

Air in the gas line.

Light a match. Turn valve knob to "PILOT" position and

 

 

 

 

 

 

depress. Keep match near pilot burner until it lights.

 

 

 

 

 

 

 

 

 

 

 

c.

Valve knob is in "OFF"

Turn valve knob to "PILOT" position and depress. Keep

 

 

 

 

 

position.

match near pilot burner until it lights.

 

 

 

 

 

 

 

 

 

 

 

d.

Pilot orifice is plugged,

This repair requires tools and some degree of

 

 

 

 

 

not allowing gas to flow.

experience. Call a qualified service technician.

 

 

 

 

 

 

 

 

 

 

 

e.

No gas supply to the

Check the plumbing to ensure the appliance has been

 

 

 

 

 

appliance.

hooked up to the gas supply line.

 

 

 

 

 

 

The propane tank is empty.

 

 

 

 

 

 

 

 

 

 

 

f.

Kink or break in line.

Replace line.

 

 

 

 

 

 

 

 

2. Pilot lights, but will not stay lit after

a.

Thermocouple too tight or

Thermocouple must be attached to the valve finger-tight,

 

 

 

carefully following lighting instruction.

 

too loose.

plus a 1/8 turn with a wrench.

 

 

 

 

 

 

 

 

 

 

 

b.

Weak pilot flame.

Pilot flame must engulf the thermocouple. Clean and/or

 

 

 

 

 

 

adjust pilot for maximum flame impingement on the

 

 

 

 

 

 

thermocouple.

 

 

 

 

 

 

 

 

 

 

 

c.

Defective thermocouple.

Check the thermocouple with a millivolt meter as follows:

 

 

 

 

 

 

Disconnect the thermocouple from the valve and connect

 

 

 

 

 

 

the red lead of the meter to the silver end of the

 

 

 

 

 

 

thermocouple. Now connect the black lead of the meter

 

 

 

 

 

 

to the copper tubing of the thermocouple. Light the pilot

 

 

 

 

 

 

and keep the knob depressed while taking readings. The

 

 

 

 

 

 

meter readings should be greater than 14 mV. If not,

 

 

 

 

 

 

replace thermocouple.

 

 

 

 

 

 

 

 

3. Pilot "ON". No gas to main burner,

a.

A blockage is preventing

Inspect the burner orifice for obstruction, including

 

 

 

valve knob "ON".

 

gas flow.

spiders and webs. Call a qualified service technician.

 

 

 

 

 

 

 

 

 

 

 

b.

Defective valve.

Replace gas valve. Call a qualified service technician.

 

 

 

 

 

 

 

 

 

4.

Irregular burn pattern.

a.

Ice & debris clog ports.

Clear away ice or debris, being careful not to force that

 

 

 

 

 

 

ice or debris into the ports.

 

 

 

 

 

 

 

 

01/04

4036-903 Rev C

11

Image 11
Contents Installation & Operating Instructions Listings and Code Approvals Table of ContentsThis page left blank intentionally Service Parts List #!5/67 Gas Line and Valve Assembly Installation Installation of the LOG SETConnect Lines to Valve Grate Assembly and Fiber Ash BedLava Rock Log PlacementLighting Instructions for the S Series Maintenance Instructions Symptoms Possible Causes Corrective Action Troubleshooting S SeriesOGL-42 Installation Instructions