Heat & Glo LifeStyle OGL-42-NG, OGL-42-LP operating instructions Installation of the LOG SET

Page 6

OGL-42 INSTALLATION INSTRUCTIONS

C. INSTALLATION OF THE LOG SET

1. Gas Line and Valve Assembly Installation

SAFETY:

This outdoor gas log set must be installed in a UL-listed outdoor fireplace that has a gas knockout on the right side with the following minimum firebox dimensions:

Depth: 19 inches

Height: 23 inches

Rear Width: 23 inches

Front Width: 42 inches

Suitable fireplaces would be STS42, OUT42, Montana.

Note: Although knockouts are provided on both sides of the fireplace, the gas inlet should be routed to the right side of the fireplace.

a.Place the burner assembly in the appliance, hand-bend the flexible stainless steel gas line as shown in Figure 1 and feed the thermocouple line, pilot line and stainless steel flexible gas line through the hole in the right side of the appliance. Make sure the excess pilot and thermocouple line is OUTSIDE the box.

b.The appliance is provided with a stainless steel flexible connector and a listed (and Commonwealth of Massachusetts approved) tee-handle manual shutoff valve.

c.Remove the right side of the valve box for easier installation of the gas line. Set aside.

1)Bend the flanges of the remaining three sides of the valve box 90° at the perforations (Figure 2), place a bead of silicone (not provided) on the back side of the flanges and slide the valve box into the square hole on the side of the FPS enclosure. (If you are not using an FPS enclosure, the valve must be located in an accessible position where one person can operate the valve and light the pilot simultaneously.) All connections within the enclo- sure need to be accessible for future maintenance or troubleshooting.

2)Secure the 3-sided valve box to the FPS enclosure with the drywall screws provided. See Figure 3.

d.Remove the valve from the valve box for ease of assembly by removing the two screws holding the valve to the valve bracket.

Note: Have the gas supply line installed in accordance with building codes by a qualified installer approved and/or licensed as required by the locality. In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter.

Figure 1 - Placing the Burner Assembly

Figure 2 - Remove Right Side of Valve Box & Bend Flanges

Figure 3 - Secure Valve Box to FPS

6

4036-903 Rev C

01/04

Image 6
Contents Installation & Operating Instructions Table of Contents Listings and Code ApprovalsThis page left blank intentionally Service Parts List #!5/67 Installation of the LOG SET Gas Line and Valve Assembly InstallationGrate Assembly and Fiber Ash Bed Connect Lines to ValveLog Placement Lava RockLighting Instructions for the S Series Maintenance Instructions Troubleshooting S Series Symptoms Possible Causes Corrective ActionOGL-42 Installation Instructions