Desa (V)KC42N, (V)KC42P Replacement Parts, Service Hints, Technical Service, Specifications

Page 31

REPLACEMENT PARTS SPECIFICATIONS SERVICE HINTS TECHNICAL SERVICE

31

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESAʼs Customer Service Depart- ment at 1-866-672-6040.

When calling DESA, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA at 1-866-672-6040 for referral information.

When calling DESA, have ready

model number of your fireplace

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply might be low (propane/LP units only)

You may feel your gas pressure is too low. If so, contact your local gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation or troubleshooting. If so, contact DESAʼs Customer Service Depart- ment at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESAʼs technical service web site at www.desatech.com.

SPECIFICATIONS

Btu

27,000/38,000 Btu/hr

25,000/36,000 Btu/hr

Gas Type

Natural

Propane/LP

Ignition

Piezo

Piezo

Manifold Pressure

3.5" w.c.

10.0" w.c.

Minimum Inlet

5.5" w.c.

11.0" w.c.

Supply Pressure

 

 

Dimension (H x W x D) Fireplace

 

 

(Actual size of firebox.

40" x 48" x 23 1/2"

40" x 48" x 23 1/2"

Measurements do not include

1016 x 1219 x 599 mm

1016 x 1219 x 599 mm

nailing flanges or standoffs).

 

 

Carton

41" x 51" x 24"

41" x 51" x 24"

 

1041 x 1295 x 610 mm

1041 x 1295 x 610 mm

Weight, lbs/kg*

 

 

Fireplace

197 lbs/89 kg

197 lbs/89 kg

Shipping

200 lbs/91 kg

200 lbs/91 kg

 

 

 

116239-01A

www.desatech.com

Image 31
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySave this manual for future reference Safety Information Table of ContentsLocal Codes Product IdentificationPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Framing and Finishing ClearancesTermination CAP AIR Supply Inlet GAS Meter Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Siding Standoff Combustible Vertical Horizontal H Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting High Altitude InstallationCheck GAS Type Venting InstallationFireplace Installation Installing Optional Blower AccessoriesBlower see Figure Model BKT InstallationBlower Wiring Diagram Installing GAS Piping to Fireplace LocationInstallation Items Needed Checking GAS Connections Connecting Fireplace to GAS SupplyOr servicing. Correct all leaks at once Pressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2REMOVING/REPLACING Glass Door Installing Remote ReceiverRemoving Louver Panels Cleaning Glass Door Installing Lava Rock and Glowing EmbersRemoving Glass Door Lighting Instructions Installing Brick Liner Models BL42DASA and BL42 DhasaFor Your Safety Read Before Lighting Operating FireplaceOptional HAND-HELD Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To ApplianceON/OFF Series Model Ghrcb Safety FeaturesManual Mode Auto Thermostatic ModeOperating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause Remedy TroubleshootingInlet gas pressure is too low Above Gas leak. See Warning statementSpecifications Replacement PartsService Hints Technical ServiceModels KC42N, KC42P, VKC42N and VKC42P Series Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListTpth TP TH Parts List Accessories Owners Registration Form Postage Required 116239-01A Warranty Information