Desa (V)KC36NE Series, (V)KC36PE Series Installing lava rock and glowing embers

Page 25

Fireplace

Installation

Continued

4.Remount the new frame at the hinge with five new screws before closing door. This will ensure seating of the gasket.

5.Close glass door frame. Lock latches by placing the bar under the tab on door and pushing down and back on latch (see Figure 37, page 24).

6.Replace screen/rod assembly by reversing step 1.

7.Replace louvers by reversing procedure under

Removing Louver Panels, page 24.

Cleaning Glass Door

See Cleaning and Maintenance on page 30.

Installing lava rock and glowing embers

It is very important to keep logs exactly as installed. Do not modify logs. Only use log set designed for this fireplace. Logs under log/grate assembly are attached to burner. Do not attempt to move these logs as this will damage logs.

WARNING: Logs are unitized and attached to the grate. Do not handle log/grate assembly by logs. Always pick up by grate.

Open louvers, remove screen, unlock door latches and open glass door. See Removing Glass Door, steps 1 and 2, page 24.

1.Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and spar- ingly directly onto the exposed front section of the burner (see Figure 38). This will create the glowing ember appearance as the flame touches the ember material. Do not block air slots by using too much ember material in one area. It is not necessary to use all of the ember material provided.

2.Pour lava rock onto plenum but not onto flat burner. It is not necessary to use all of the lava rock provided.

NOTICE: Do not put lava rock on burner or under burner. Placing lava rock on burner will cause performance problems.

3.Close glass door, lock door latches, replace screen and close louvers (see Removing Glass Door, steps 5 through 7).

WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken.

Andiron

Plenum

Ember Material

Figure 38 - Placing Ember Material on

Burner

Installing Brick liner Models BL36DA(SA) and BL36DHA(SA)

WARNING: If fireplace has been running, turn off unit. Let cool before installing brick liner.

You may purchase brick liner from your local retailer or see Accessories, page 35.

CAUTION: Always handle brick panels with two hands. Do not force brick panels into place. Excessive force will break brick panels.

1.Remove top and bottom louvers to allow ac- cess to door latches.

2.Unlock door latches and open glass door. See Removing Glass Door, steps 1 and 2, page 24.

3.Carefully remove lava rock and ember material.

4.Remove and iron assembly from plenum by removing screws.

5.Carefully lift logs and ember pod from burner

6.Remove screws that attach plenum to burner to remove plenum.

116238-01E

www.desatech.com

25

Image 25
Contents Patent Pending What to do if YOU Smell GASSafety Information Table of ContentsSafety information Local Codes Product IdentificationHigh traffic areas Pre-Installation Preparation Product FeaturesLocation and space requirements Framing and finishing ClearancesFront Top of Standoffs Vent For specific ventingClearances for Combustible Mantels Balcony with Perpendicular Side Wall Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Round Termination Square TerminationRecommended Applications Corner ground floor installation Corner InstallationHorizontal System Installation Using TWO 90 Elbows Flat Ceiling Installation Installation for vertical terminationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsInstalling optional blower accessories Fireplace InstallationModel BK Installation Plug in blower power cordBlower Model BKT Model BKT InstallationBlower Wiring Diagram Installing Gas Piping to Fireplace LocationInstallation Items Needed Propane/LP Supply TankExternal Regulator Vent Pointing Down Connecting Fireplace to GAS SupplyTest Pressures Equal To or Less Than Psig 3.5 kPa Checking GAS ConnectionsClose equipment shutoff valve see Figure Disconnect fireplace and its individual equipRemoving Louver Panels Pressure Testing Fireplace Gas ConnectionsRemoving Glass Door Installing Brick liner Models BL36DASA and BL36DHASA Installing lava rock and glowing embersReplace screen/rod assembly by reversing step Cleaning Glass DoorOptional Remote control Installation model WRC Wall Switch InstallationReplace top and bottom louvers Pilot Wiring DiagramOperating Fireplace For your safety Read before lightingLighting Instructions To Turn OFF GAS To AppliancePilot Assembly Operating optional blower accessoryInspecting Burners Optional Remote OperationGlass Door Cleaning MaintenancePilot and burners LogsObserved Problem Possible Cause Remedy TroubleshootingVenting system Ule And/or check ground wire to Check wiring connectionNo gas to burner, although wall Wall switch wires defective Low, causing safety pilot toGas leak. See Warning Statement at topService Hints Replacement PartsTechnical Service SpecificationsAccessories Models KC36NE, VKC36NE, KC36PE and VKC36PE series Illustrated Parts BreakdownParts List 19 18 31 33 116238-01E Firebox Bottom Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace