Desa CGCF26TN Specifications, Replacement Parts, Service Hints, Technical Service

Page 23

SPECIFICATIONS REPLACEMENT PARTS SERVICE HINTS TECHNICAL SERVICE

23

SPECIFICATIONS

 

CGCF26TP

CGCF26TN

Btu (Variable)

14,000/26,000

14,000/26,000

Type Gas

Propane/LP Only

Natural Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

8" W.C.

3" W.C.

Inlet Gas Pressure (in. of water)*

 

 

Maximum

14"

10.5"

Minimum

11"

5"

Dimensions, Inches (H x W x D)

 

 

Fireplace

25 7/8 x 26 13/16 x 9 3/8

25 7/8 x 26 13/16 x 9 3/8

Carton

32 5/8 x 27 3/16 x 11 5/8

32 5/8 x 27 3/16 x 11 5/8

Weight, pounds

 

 

Fireplace

44 1/2 lbs.

44 1/2 lbs.

Shipping

48 lbs.

48 lbs.

* For purposes of input adjustment

 

 

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA Heating Products’ Techni- cal Service Department at 1-866-672-6040 for referral information.

When calling DESA Heating Products, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product or Parts Central (see page 26). If they can’t supply original replacement part(s) call DESA Heating Products at 1-866-672-6040 for referral information.

When calling DESA Heating Products, have ready:

model number of your fireplace

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burner will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply may be low (propane/LP only)

You may feel your gas pressure is too low. If so, contact your local propane/LP or natural gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ technical service web site at www.desatech.com.

For morevisit www..com

111044-01A

Image 23
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Local CodesUnpacking Product FeaturesAssembly Unusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Assembling HoodDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Ventilation Air From Inside Building InstallationVentilation AIR Check GAS TypeLocating Fireplace Installation ItemsRough Opening for Installing in Wall BUILT-IN Fireplace InstallationOptional Mantel Installation Mantel Clearances for BUILT-IN InstallationRemoving Upper Louver Assembly Installing Blower Accessory GA3450TRemoving Valve Cover Shield Installing Blower AssemblyOutlet For Built-In InstallationExtension Cord Connecting to GAS SupplyAttaching Wood Base to Solid Floor Installation Items Needed Connecting Equipment Shutoff Valve to Heater ControlChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Inspecting Burner Air Passageways Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole CabinetObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Technical Service SpecificationsReplacement Parts Service HintsModels CGCF26TP and CGCF26TN Illustrated Parts BreakdownKEY CGCF26TP CGCF26TN Description QTY Parts ListParts Centrals Owners Registration Form Postage Required Accessories Warranty Information