Desa CGCFTP Mantel Clearances for BUILT-IN Installation, Optional Mantel Installation

Page 10

CGCFTP

VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE

INSTALLATION

Continued

MANTEL CLEARANCES FOR BUILT-IN INSTALLATION

If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.

NOTICE: Surface temperatures of adjacent walls and mantels be- come hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these tempera- tures meet the requirement of the national product standard. Fol- low all minimum clearances shown in this manual.

NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following:

raise the mantel to an accept- able height

remove the mantel

Mantel Shelf

Note:

10"

8"

All vertical

measurements

6"

are from top of

2 1/2"

fireplace

opening to bottom of mantel shelf. All measurements are in inches.

13"

16"

19"

21"

Side of

Firebox

OPTIONAL MANTEL

INSTALLATION

Note: Refer to instructions provided with the mantel for assembly instructions. Refer to instructions below for system installa- tion. Refer to instructions on page 4 for firebox assembly. Blower accessory should be installed if it is being used (see Installing Blower Accessory GA3450T, pages 11 through 13).

1.Unscrew four brass screws that attach top louver to fireplace. Remove louver from fireplace and set aside.

2.Place fireplace on wood base.

3.Place mantel around fireplace/base assembly.

4.Assemble brass trim kit. See Assem- bling Brass Trim, page 11.

5.Firmly snap brass trim kit on shoulder screws. Shoulder screws are located on fireplace cabinet (see Figure 13).

6.Align brass trim kit for flush fit around opening.

7.Use two 3" wood screws provided and attach fireplace base to wooden base (see Figure 13).

Shoulder Screws

Hole for 3" Wood Screw for Attaching Fireplace to Mantel

Assembled

Brass Trim

8.Remove brass trim kit and mantel. Be careful not to damage wall or mantel.

9.Place wood base next to wall at instal- lation location.

10.Attach wood base to floor with two 1 3/4" black screws provided (see Figure 14). If the floor is concrete use anchor method (see Attaching Wood Base to Solid Floor, page 14).

11.Install gas line. See Connecting To Gas Supply, page 14.

12.Check for leaks. See Checking Gas Connections, page 16.

13.Place mantel around fireplace. Be care- ful not to damage wall or mantel.

14.Place brass trim kit on the shoulder screws located on the side and top of the fireplace. Firmly snap the brass trim over the shoulder screws on fireplace (see Figure 13).

15.Adjust assembly to remove any gaps. Attach remaining two 3" wood screws from hardware pack through openings inside of fireplace sides into the mantel. The openings are located at top behind the area for the louvers (see Figure 13).

16.Reinstall top louvers.

Hole for 3" Wood Screw for Attaching Fireplace to Wooden Base

Figure 12 - Minimum Mantel Clearances for Built-In Installation

Figure 13 - Attaching Brass Trim to Fireplace

1 3/4" Screw

Wood Base

Figure 14 - Attaching Wood Base to Floor

10

107036

Image 10
Contents VENT-FREE PROPANE/LP GAS Compact Fireplace What to do if YOU Smell GASSafety Information Cgcftp VENT-FREE PROPANE/LP GAS Compact FireplaceLocal Codes Product FeaturesUnpacking Product IdentificationAssembling Fireplace AssemblyInstalling Log Assembling HoodUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Locating Fireplace InstallationInstallation Items Check GAS TypeBUILT-IN Fireplace Installation Rough Opening for Installing in WallMantel Clearances for BUILT-IN Installation Optional Mantel InstallationInstalling Blower Assembly Installing Blower Accessory GA3450TRemoving Upper Louver Assembly Removing Valve Cover ShieldInstall the switch plate on the valve For Built-In Installation Wiring Diagram For Blower Accessory Built-In InstallationAttaching Wood Base to Solid Floor Connecting to GAS SupplyExtension Cord Connecting Equipment Shutoff Valve to Heater Control Installation Items NeededPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Operating Fireplace For Your Safety Read Before LightingLighting Instructions Inspecting Burner Troubleshooting Observed Problem Possible Cause RemedyBurner damaged Gas leak. See Warning statement at Replacement Parts Cleaning and MaintenanceService Hints Technical Service SpecificationsParts Centrals Illustrated Parts Breakdown CgcftpParts List KEY CGCF26TP Description QTYAccessories 107036 Warranty Information