15.Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and re- pair fireplace.

16.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

17.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

18.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

PRODUCT

FEATURES

SAFETY PILOT

This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room fireplaces. The ODS/ pilot shuts off the fireplace if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This sys- tem requires no matches, batteries, or other sources to light fireplace.

UNPACKING

1.

Remove log box and fireplace from

 

carton. IMPORTANT: The fireplace

 

hood is inside the cardboard protective

 

end wrap on the left side of fireplace

 

(as viewed from front). A decal is on

 

the outside of the cardboard end wrap

 

stating hood is enclosed (see Figure 2).

2.

Remove hood from cardboard protec-

 

tive end wrap as shown in Figure 2.

3.

Remove all protective packaging ap-

 

plied to fireplace for shipment.

4.

Make sure your fireplace includes one

 

hardware packet.

5.

Check fireplace for any shipping

 

damage. If fireplace is damaged,

19.Provide adequate clearances around air openings.

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

THERMOSTATIC HEAT CONTROL

This fireplace has a thermostat sensing bulb and a control valve. The thermostat will automatically modulate the heat output to maintain a consistent room temperature. This results in greater fireplace comfort. This can also result in lower gas bills.

promptly inform dealer where you

bought fireplace.

Hood Enclosed

IMPORTANT:

THIS PACKAGE CONTAINS A

Decal

FIREPLACE HOOD. UNWRAP

 

CARTON AND REMOVE HOOD

 

BEFORE DISCARDING

 

PROTECTIVE PACKAGING.

 

Cardboard

 

Protective

 

Fireplace

 

End Wrap

 

2

PRODUCT IDENTIFICATION

Fireplace

Cabinet

Screen

Log Set

Control Knob

Ignitor Button

Figure 1 - Vent-Free Gas Compact Fireplace

1

Hood

Figure 2 - Removing Fireplace Hood

107036

3

Image 3
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GAS Compact FireplaceCgcftp VENT-FREE PROPANE/LP GAS Compact Fireplace Safety InformationProduct Identification Product FeaturesUnpacking Local CodesAssembling Hood AssemblyInstalling Log Assembling FireplaceConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationInstallation Items Locating FireplaceRough Opening for Installing in Wall BUILT-IN Fireplace InstallationOptional Mantel Installation Mantel Clearances for BUILT-IN InstallationRemoving Valve Cover Shield Installing Blower Accessory GA3450TRemoving Upper Louver Assembly Installing Blower AssemblyInstall the switch plate on the valve Wiring Diagram For Blower Accessory Built-In Installation For Built-In InstallationConnecting to GAS Supply Attaching Wood Base to Solid FloorExtension Cord Installation Items Needed Connecting Equipment Shutoff Valve to Heater ControlPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Inspecting Burner Observed Problem Possible Cause Remedy TroubleshootingBurner damaged Gas leak. See Warning statement at Cleaning and Maintenance Replacement PartsService Hints Specifications Technical ServiceParts Centrals Cgcftp Illustrated Parts BreakdownKEY CGCF26TP Description QTY Parts ListAccessories 107036 Warranty Information