OWNER’S MANUAL
INSTALLATION
Continued
ASSEMBLING BRASS TRIM (Brass trim shipped with mantel)
1.Remove packaging from three remain- ing pieces of brass trim.
2.Locate two adjusting plates with set screws, and two shims in the hardware packet.
3.Align shim under adjusting plate as shown in Figure 15.
4.Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 15).
5.Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 15).
6.While firmly holding edges of brass trim together, tighten both set screws on the adjusting plate with slotted screwdriver.
7.Repeat steps 1 through 6 for other corner.
8.Set brass assembly aside for later in- stallation.
Top Brass Trim
INSTALLING BLOWER ACCESSORY GA3450T
Removing Upper Louver
Assembly
To install the blower accessory, you must first remove the upper louver assembly.
1.Lift screen off heater.
2.Remove 4 screws from louver assem- bly (see Figure 16). Save these screws.
3.Pull louver assembly straight out from the cabinet. Be careful not to scratch the paint. Set louver assembly and screws aside.
Blower Bracket
Mounting Holes
Upper Louver
Assembly
Screws
Figure 16 - Removing Upper Louver Assembly
Branch
Shoulder Support
Screw
Remove
Screw
Valve
Cover
Shield 2
1
Bottom Louver
SnapAssembly
Bushings
Figure 17 - Removing Valve Cover Shield
Installing Blower Assembly
CAUTION: Label all wires prior to disconnection when ser- vicing controls. Wiring errors can cause improper and danger- ous operation.
SetSlot Screws
Shim
Mitered Edge
Removing Valve Cover Shield
1. | Open bottom louver assembly by |
| swinging the assembly down (see Fig- |
| ure 17). |
2. | Using short Phillips screwdriver, re- |
CAUTION: Verify proper op- eration after servicing.
Note: If you are using a mantel with your heater, use the following instructions. If your heater is
Adjusting Plate
Side Brass Trim
move the screw under the center of the |
branch support. Rotate valve cover |
shield clockwise and slide out. |
IMPORTANT: Do not remove shoul- |
stallation on page 13.
1. Install snap bushings found in hardware |
kit into both holes in rear of valve cover |
shield. |
Slot
Figure 15 - Assembling Brass Trim
der screw on the left side of valve cover |
shield. Slide the valve cover shield off |
of the shoulder screw (see Figure 17). |
Note: If you do not have a short |
Phillips screwdriver, the screen, log set, |
and branch support must be removed |
so a longer screwdriver may be used. |
See Connecting Fireplace To Gas Sup- |
ply, page 15 and follow step 2. |
2. Make sure the wire harness is firmly |
connected to the terminals on the blower |
bracket assembly. |
3. Note the wire locations on back of |
AUTO/OFF/ON switch. The terminals |
on back of switch are numbered 1, 2, |
and 3. Carefully remove red wire from |
terminal 1 and blue wire from terminal |
3. Black wire can remain on middle |
terminal 2 (see Figure 18, page 12). |
Continued
107036 | 11 |