Desa CGCFTN installation manual Gas leak. See Warning statement at

Page 21

OWNER’S MANUAL

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most fireplaces. If noise is excessive, contact qualified ser- vice person

Fireplace produces unwanted odors

1.

Fireplace burning vapors from paint, hair

 

 

spray, glues, etc. (see IMPORTANT

 

 

statement above)

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Ventilate room. Stop using odor caus- ing products while fireplace is running

2.Locate and correct all leaks (see Check- ing Gas Connections, page 16)

Fireplace shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local natural gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 22)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Check-

position

 

top of page

 

ing Gas Connections, page 16)

 

2.

Control valve defective

2.

Replace control valve

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 16)

Moisture/condensation noticed on windows 1. Not enough combustion/ventilation air

1. Refer to Air for Combustion and Venti-

 

lation requirements (page 5)

www.desatech.com

107035

21

Image 21
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualCgcftn VENT-FREE Natural GAS Compact Fireplace Safety InformationLocal Codes Product FeaturesUnpacking Product IdentificationInstalling Log AssemblyAssembling Fireplace Assembling HoodProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Items InstallationLocating Fireplace Check GAS TypeRough Opening for Installing in Wall BUILT-IN Fireplace InstallationOptional Mantel Installation Mantel Clearances for BUILT-IN InstallationRemoving Upper Louver Assembly Installing Blower Accessory GA3450TInstalling Blower Assembly Removing Valve Cover ShieldInstall the switch plate on the valve Wiring Diagram For Blower Accessory Built-In Installation For Built-In InstallationConnecting to GAS Supply Attaching Wood Base to Solid FloorExtension Cord Installation Items Needed Connecting Equipment Shutoff Valve to Heater ControlPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Inspecting Burner Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Specifications Technical ServiceParts Centrals Cleaning and Maintenance Replacement PartsService Hints Cgcftn Illustrated Parts BreakdownKEY Description QTY Parts ListAccessories 107035 Warranty Information