VENTING INSTALLATION INSTRUCTIONS
Installation for Vertical Termination (Cont.) High Altitude Installation Parts Lists for Venting Kits and Components for V42 and VV42 Series
15
VENTING INSTALLATION INSTRUCTIONS
Continued
Vertical Venting
V = 40' max.
Note: Install restrictor into inner collar of fireplace as shown.
45° Elbow
Figure 24 - Vertical Venting Configuration With No Horizontal Run (Vertical Round High Wind Termination Shown)
HIGH ALTITUDE INSTALLATION
Your DESA
When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification.
When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities.
Consult your local gas company to help determine the proper orifice for your location.
For assistance with any high altitude installation contact DESA’s Customer Service Department at
PARTS LISTS FOR VENTING KITS AND COMPONENTS FOR V42 AND VV42 SERIES DESA (5/8") Pipe & Vent Kits
Number Description
nized
HTK Horizontal Round Termination Kit