Desa (V)V42ENA(1) Series, (V)V42EPA(1) Series Wiring Diagram, Wall Switch Installation

Page 24

24

FIREPLACE INSTALLATION

Wall Switch Installation

Optional Remote Control Installation

WIRING DIAGRAM

FIREPLACE INSTALLATION

Continued

WALL SWITCH INSTALLATION

The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off. The wall switch is to be connected to the incoming 120 volt regular household wiring that supplies the electricity to the fireplace. Refer to wiring diagram below.

OPTIONAL REMOTE CONTROL

INSTALLATION (Model WRC)

Note: If using optional wireless hand-held remote control, the wall switch must be in the ON position to be operational. The remote control then becomes the switching mechanism for fireplace operation.

1.Open lower louver panel.

2.The WRC model receiver does not require a battery. The re- ceiver can be installed by first plugging the short extension cord into the fireplace receptacle. Then plug the receiver unit into the extension cord. Finally plug the ignition module plug into the receiver unit (see Figure 47).

3.Activate the remote handset battery by removing the insulat- ing tab on the back of the handset (see Figure 48). The battery is included pre-installed.

4.Once the battery is activated the unit is ready to use.

5.Close lower louver panel.

Fireplace

Receptacle

Remote Control

Receiver

Extension Cord

Ignition

Module Plug

Figure 47 - Installing the WRC Remote Receiver

Battery Cover

12 Volt Battery

Back of

Handset Pull to Remove

Insulation Tab

Figure 48 - Installing Battery into Back of Handset

WIRING DIAGRAM

INCOMING MAIN

GAS SUPPLY

EV1

EV2

GAS LINE TO

BURNER

Pilot

Burner

Pilot Gas

Line

MV

TH

PV/MV

TR

GND

PV

IGN

24V AC

STEP DOWN

TRANSFORMER

120V AC

WALL SWITCH (SUPPLIED)

ON

OFF

BLACK

INCOMING

 

WHITE

120V AC

GREEN

(FUSE BOX

OR BREAKER)

 

BLACK

WHITE

GREEN

ELECTRICAL RATING:

120v, 60Hz, 0.7A

OPTIONAL

REMOTE

CONTROL

For..com

111907-01C

Image 24
Contents OWNER’S Operation Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Table of Contents Safety InformationProduct Identification Local CodesProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Clearances Framing and FinishingLocation of Termination CAP Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal Termination Configurations Ground Floor InstallationCorner Installation Venting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations High Altitude Installation Number DescriptionFireplace Installation Installing Optional Blower AccessoryCheck GAS Type Attaching Speed Control to Firebox Model BKT Installation Blower Wiring DiagramInstalling GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Louver PanelsInstalling Optional Brick Liner Models BL42DASA, BL42DHASA Installing LOGS, Lava Rock and Glowing EmbersInstalling Log No and Log No Wiring Diagram Wall Switch InstallationOptional Remote Control For Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Burner Flame PatternCleaning Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause Illustrated Parts Breakdown ModelsParts List Description QTYBurner Assembly for Models VV42ENA1, VV42ENSA1 KEY Part Number Description QTY Replacement Parts Service HintsTechnical Service SpecificationsOwners Registration Form Postage Required Accessories Warranty Information