Desa CF26NT installation manual Installing Logs, Pressure Testing Fireplace Gas Connections

Page 15

INSTALLATION

Checking Gas Connections (Cont.) Installing Logs

15

INSTALLATION

Continued

Equipment Shutoff Valve

Propane/LP

Supply Tank

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

Place one-piece log set on grate to fit as illustrated in Figure 27. Make sure back section of log set is seated into “U”-shaped cutout in center of chassis (see Figure 27). IMPORTANT: Make sure log does not cover any burner ports (see Figure 28).

One Piece Log Set

Figure 26 - Checking Gas Joints for Propane/LP Units (Shown with Optional Mantel)

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Figure 24, page 14).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Figure 23, page 14). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light fireplace (see Operating Fireplace, pages 16 and 17). Check all other internal joints for leaks.

7.Turn off fireplace (see To Turn Off Gas to Appliance, page 16).

8.Replace front panel.

INSTALLING LOGS

WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: After installation and periodically there- after, check to ensure that no flame comes in contact with any log. With the heater set to HI, check to see if flames contact any log. If so, reposition logs accord- ing to the log installation instructions in this manual. Flames contacting logs will create soot.

Burner

 

LO

 

HI

 

T FF

Chassis

PILOO

"U"-shaped

 

Cutout in

 

Chassis

Figure 27 - Installing One-Piece Log Set

Burner Ports

One Piece Log Set

 

Figure 28 - Installing One-Piece Log set (Top View)

For morevisit www..com

111410-01C

Image 15 Contents
What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsVent-Free Bay Front Compact Fireplace Product IdentificationAIR for Combustion and Ventilation Product FeaturesLocal Codes UnpackingDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building InstallationVentilation AIR Check GAS TypeLocating Fireplace Rough Opening for Installing in Wall BUILT-IN Fireplace InstallationAssembling Trim Optional Mantel InstallationMantel Clearances for Built-In Installation Removing Brick Liner RetainerRemoving Screen Installing Blower Assembly GA3450T Installing Blower Bracket Assembly For Built-In InstallationInstallation Items Connecting to GAS SupplyInstallation Items Needed Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Installing LogsTo Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsInspecting Burners Cleaning MaintenanceCabinet SpecificationsService Hints Technical ServiceObserved Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Top Models CF26PT Shown CF26NT Illustrated Parts BreakdownKEY Part Number CF26PT CF26NT Description QTY Parts ListModels CF26PT and CF26NT KEY Description QTY Parts Centrals Replacement PartsParts Under Warranty Parts not Under WarrantyOwners Registration Form Postage Required Corner Mantel with Full Hearth Base AccessoriesBrass Accent Trim GA6095 Cabinet Mantel with Full Hearth BaseKeep this Warranty Warranty Information