Built-In Fireplace Installation (Cont.)

Removing Brick Liner Retainer

Assembling Trim

Optional Mantel Installation

9

INSTALLATION

Continued

IMPORTANT: Noncombustible materials such as brick, tile, etc. may overlap the front facing, but should never cover any necessary openings like louvered slots.

WARNING: Do not allow noncombustible materials to cover any necessary openings like louvered slots.

WARNING: Never modify or cover the louvered slots on the front of the firebox.

WARNING: Use only noncombustible mortar or adhesives when overlapping the front facing with noncombustible facing material.

Mantel Clearances for Built-In Installation

If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.

NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.

NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following:

raise the mantel to an acceptable height

remove the mantel

REMOVING BRICK LINER RETAINER

1.Using Phillips screw driver, remove 2 screws attaching brick liner retainers to vertical sides.

2.Remove brick liner retainers and discard. Replace 2 screws into vertical sides.

ASSEMBLING TRIM

(Trim shipped with mantel)

1.Remove packaging from three pieces of trim.

2.Locate two adjusting plates with set screws, and two shims in the hardware packet.

3.Align shim under adjusting plate as shown in Figure 10.

4.Slide one end of adjusting plate/shim in slot on mitered edge of top trim (see Figure 10).

5.Slide other end of adjusting plate/shim in slot on mitered edge of side trim (see Figure 10).

6.While firmly holding edges of trim together, tighten both set screws on the adjusting plate with slotted screwdriver.

7.Repeat steps 1 through 6 for other corner.

8.Set brass assembly aside for later installation.

Set Screws

Slot

Top Trim

Adjusting

 

Plate

Mitered Edge

Shim

Side Trim

 

Slot

Figure 10 - Assembling Trim

Note: All vertical measurements are from top of fireplace opening to bottom of mantel shelf.

Minimum Non-

Combustible

Material

10"

8"

6"

2 1/2"

13"

16"

Mantel Shelf

19"

 

21"

 

 

 

 

OPTIONAL MANTEL INSTALLATION

Note: Refer to instructions provided with the mantel for assembly instructions. Refer to instructions below for system installation. If using blower accessory (see Accessories, page 29), see installation instructions on pages 11 and 12.

1.

Choose location for fireplace and install gas supply line.

2.

Remove screen from fireplace by removing screws in each

 

end of screen rod (see Figure 11, page 10). Hold screen rod

 

cover while removing five hex head screws underneath hood

 

(see Figure 12, page 10). Carefully lift and pull out hood (see

 

Figure 13, page 10).

3.

Assemble trim kit. See Assembling Trim, above.

4.

Place trim on the shoulder screws located on the side and top

 

of the fireplace. Firmly snap the trim over the shoulder screws

 

on fireplace (see Figure 14, page 10).

5.

Place mantel base close to wall in desired fireplace location.

6.

Install gas line. See Connecting To Gas Supply, pages 12 and 13.

Figure 9 - Minimum Mantel Clearances for Built-In Installation

For morevisit www..com

111410-01C

Image 9 Contents
What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsVent-Free Bay Front Compact Fireplace Product IdentificationLocal Codes Product FeaturesUnpacking AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location Confined and Unconfined Space Determining if You Have a Confined or Unconfined Space Ventilation AIR InstallationCheck GAS Type Ventilation Air From Inside BuildingLocating Fireplace Rough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationRemoving Brick Liner Retainer Assembling TrimRemoving Screen Installing Blower Assembly GA3450TInstalling Blower Bracket Assembly For Built-In InstallationInstallation Items Connecting to GAS SupplyInstallation Items Needed Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Installing LogsOperating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To ApplianceInspecting Burners Cleaning MaintenanceService Hints SpecificationsTechnical Service CabinetObserved Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Top Models CF26PT Shown CF26NT Illustrated Parts BreakdownKEY Part Number CF26PT CF26NT Description QTY Parts ListModels CF26PT and CF26NT KEY Description QTY Parts Under Warranty Replacement PartsParts not Under Warranty Parts CentralsOwners Registration Form Postage Required Brass Accent Trim GA6095 AccessoriesCabinet Mantel with Full Hearth Base Corner Mantel with Full Hearth BaseKeep this Warranty Warranty Information